  • Page 1 FU-W53J Plasmacluster is a trademark of Sharp Corporation. AIR PURIFIER OPERATION MANUAL Free standing type...
  • Page 2 Please read before operating your new Air Purifier The air purifier draws in room air via its air intake, letting the air pass through an Active Carbon Filter (deodorisation filter) and a HEPA Filter (dust collection filter) inside the unit, then discharges the air from its air outlet. The air purifier unit repeats this process continuously when its internal fan is working.
  • Page 3: Table Of Contents

    13m² lab using an air sampler. *4 Japan Spinners Inspecting Foundation, Japan Evaluation of deodorising effect on Thank you for purchasing the SHARP Air Puri- odour-imbued fragments of cloth fier. Please read this manual carefully for the correct usage information. Before using this product, be sure to read the section: “Important...
  • Page 4: Important Safety Instructions

    • Be cautious when cleaning the unit. Strong corrosive cleansers may damage the exterior. • Only Sharp Approved Service Centres should service this air purifier. Contact your nearest Ap- proved Service Centre for any problems, adjustments, or repairs. • This appliance is not intended for use by persons (including children) with reduced physical, sen- sory or mental capabilities, or lack of experience and knowledge, unless they have been given su- pervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 5: Cautions Concerning Operation

    IMPORTANT SAFETY INSTRUCTIONS CAUTIONS CONCERNING OPERATION • Do not block the air intake and/or outlet. • Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into contact with steam. • Do not lay the unit down when turned on. •...
  • Page 6: Part Names

    PART NAMES MAIN UNIT DISPLAY Fan Speed Indicator Lights Filter Reset Indicator Light Plasmacluster ON/OFF Indicator Light Plasmacluster Ion ON/OFF Button Fan Speed Button ION SHOWER Indicator Light ION SHOWER Mode Button ILLUSTRATIVE DIAGRAM Date Label Odour Sensor Main Unit HEPA Filter Washable Active Carbon Filter Filter Support Front Panel...
  • Page 7: Back

    Plasmacluster Indicator Light(Blue) Blue light : Plasmacluster ON Light off : Plasmacluster OFF CLEAN - SIGN Light Clean Slightly Impure Very Impure The colour changes according to the air condition. Green Yellow ABOUT THE CLEAN-SIGN • The condition of the CLEAN-SIGN depends on the room air condition detect- ed by the Dust and Odour Sensors when the plug is inserted into the wall outlet.
  • Page 8: Preparation

    PREPARATION Be sure to remove the power plug from the wall outlet. FILTER INSTALLATION To maintain the quality of the filters, they are installed in the main unit and packed in plastic bags. Be sure to remove the filters from the plastic bags before using the unit. Remove the filters Front Panel Remove the Front Panel. Pull the Front Panel on the lower sides, and lift up. Remove the Filter Support. Push in the hooks on top, then pull the Filter Support. Filter Support Remove the washable Active Carbon Filter (Black) and HEPA Filter (White) from the plastic bags.
  • Page 9 Install the filters Place the HEPA Filter into the main unit. Please make sure that the HEPA Filter(blue) and the tab is placed (blue) in proper direction. Do not install the filter backwards or the HEPA Filter unit will not operate properly. Insert two bottom tabs (left and right) of the Filter Support into the small holes in the unit, and slide the Active Active Carbon Filter...
  • Page 10: Operation

    OPERATION MAIN UNIT OPERATION FAN Speed Indicator Lights FAN SPEED Button Power ON/OFF Button Plasmacluster • Used to start operation (short beep) and ON/OFF Button stop operation (long beep) • Plasmacluster Indicator Light and Fan Speed Indicator Light turn on/off. • Unless the power cord is unplugged, the op- eration will start in the previous mode.
  • Page 11: Adjustment Of Sensor Detection Sensitivity

    Plasmacluster Indicator Light CLEAN - SIGN Light POWER ON/OFF Button LIGHT CONTROL Button ION SHOWER Mode Button Plasmacluster ON/OFF Button Press the Plasmacluster ON/OFF Button to turn Plasmacluster Ion Mode ON and OFF. When Plasmacluster is ON, both the Indicator Light and Plasmaclus- ter Indicator will turn on.
  • Page 12: Care And Maintenance

    CARE AND MAINTENANCE To maintain optimum performance of this air purifier, please clean the unit including the sen- sor and filters periodically. When cleaning the unit, be sure to unplug the power cord, and nev- er handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result. FILTER RESET INDICATOR LIGHT The Filter RESET Indicator Light will illuminate as a reminder to perform mainte- nance of the Filters and Sensors.The Indicator Light will turn on after approximately 720 hours of use. After performing maintenance, reset the Filter Reset Indicator. Plug the unit in, turn power ON, and press the Plasmacluster Ion ON/OFF Button for 3 seconds.
  • Page 13: Washable Active Carbon Filter Care

    WASHABLE ACTIVE CARBON FILTER CARE Care Cycle 2 months HAND WASH ONLY! DO NOT TUMBLE DRY! HEPA Filter Washable Active Carbon Filter Rinse dirt from the WASHABLE ACTIVE CARBON FILTER under lukewarm water. Remove dust on the washable active carbon filter before washing. CAUTION • When washing the filter for the first time, the rinse water may be brown.
  • Page 14: Filter Replacement Guidelines

    CARE AND MAINTENANCE FILTER REPLACEMENT GUIDELINES The replacement period differs depending on the room environment, the usage hours and location of the Air Purifier. If dust or odour persist, replace the filters. (Refer to “Please read before operating your new Air Purifier”) HEPA Filter / Washable Active Carbon Filter Up to 5 years after opening Guide for filter replacement timing • Filter life can be greatly reduced in a poor environment. The presence of cigarette smoke, pet dander and other concentrations of airborne particles will cause filters to become clogged in less time.
  • Page 15: Troubleshooting

    Light Control Button to activate the indicator lights. will not activate. (Refer to E-9) If you still require service, contact your SHARP approved service centre. SHARP approved service centre locations can be found in the support area of our website: Australia : http://www.sharp.net.au New Zealand : http://www.sharp.net.nz ERROR DISPLAY...
  • Page 16: Specifications

    SPECIFICATIONS Model FU-W53J 220-240V 50Hz Power supply SILENT Fan Speed Adjustment 3.5W(3.2W) Rated Power Speed Operation 204m /hour /hour 318m /hour Fan Speed ~41m 2 *2 Recommended Room Size High density Plasmacluster ion applicable floor surface ~20m 2 *3 Cord Length 2.0m 338mm(W)x205mm(D)x620mm(H) Dimensions...