Figure 193. Spindle Motor Degraded Mode - Auto Start Delay/Spinning Up - IBM IC35L036UWDY10 - Ultrastar 36.7 GB Hard Drive Specifications

3.5 inch scsi hard disk drive
Table of Contents

Advertisement

Command (w/Option)
REQUEST SENSE
INQUIRY
REPORT LUNS
TEST UNIT READY
START STOP UNIT
(Start)
Other Commands

Figure 193. Spindle Motor Degraded Mode - Auto Start Delay/Spinning Up

Response
Executed. The drive may return Sense KCQ
020401h (NOT READY, IN PROCESS OF BECOMING
READY)
Executed
Executed
Executed and CHECK CONDITION is returned
with Sense KCQ 020401h (NOT READY, IN
PROCESS OF BECOMING READY)
Executed
- Success: GOOD status is returned. Spindle
Motor Degraded Mode is cleared
- Spindle Motor Start Failure: CHECK
CONDITION with Sense KCQ 020400h (NOT
READY, START SPINDLE MOTOR FAIL)
- Bring-up Failure: CHECK CONDITION with
Sense KCQ 024080h (NOT READY, DIAG FAIL -
BRING-UP FAIL) or Sense KCQ 024085h (NOT
READY, DIAG FAIL - RAM CODE NOT LOADED)
Not Executed. CHECK CONDITION is returned
with Sense KCQ 020401h (NOT READY, IN
PROCESS OF BECOMING READY)