Command (w/Option)
REQUEST SENSE
INQUIRY
REPORT LUNS
TEST UNIT READY
START STOP UNIT
(Start)
START STOP UNIT
(Stop)
Other Commands
Figure 195. Spindle Motor Degraded Mode - Spindle Stopped by START STOP UNIT Command
Response
Executed. The drive may return Sense KCQ
020402h (NOT READY, INITIALIZE COMMAND
REQUIRED)
Executed
Executed
Executed and CHECK CONDITION is returned
with Sense KCQ 020402h (NOT READY,
INITIALIZE COMMAND REQUIRED)
Executed
- Success: Good status is returned. Spindle
Motor Degraded Mode is cleared
- Spindle Motor Start Failure: CHECK
CONDITION with Sense Key 020400h (NOT
READY, START SPINDLE MOTOR FAIL)
- Bring-up Failure: CHECK CONDITION with
Sense KCQ 024080h (NOT READY, DIAG FAIL -
BRING-UP FAIL) or Sense KCQ 024085h (NOT
READY, DIAG FAIL - RAM CODE NOT LOADED)
Executed.
GOOD Status is returned.
Degraded Mode is NOT cleared
Not Executed. CHECK CONDITION is returned
with Sense KCQ 020402h (NOT READY,
INITIALIZE COMMAND REQUIRED)
Ultrastar 146Z10 hard disk drive specifications
201
Motor