12.
If you want all ports to be shut when restoring the switch configuration, edit the last backed up switch
configuration file and change all the interface ports to shutdown. For example:
switch# interface bay1
switch# port-license acquire
switch# no shutdown <- change to shutdown
13.
Save the switch configuration file after making your edits.
14.
Restore the switch configuration from the remote server.
15.
Verify that all ports acquire a license:
switch# show port-license
16.
If all ports have not been acquired, acquire them.
17.
Reset the SNMP admin password to enable Device Manager and Fabric Manager SNMP login.The
following example shows the CLI commands:
switch# config t
switch(config)# snmp-server user admin auth md5 new password
switch(config)# copy running-config startup-config
For instructions on completing Steps 16 and 17, see the Cisco Fabric Manager Fundamentals
Configuration Guide and the Cisco MDS 9000 Family Fundamentals Configuration Guide.
18.
Connect all external fibre channel cables in the same port location as before. All interfaces should
remain in the shutdown state until you re-enable them on the switch using the no shutdown
command.
19.
Verify that the switch successfully joins the fabric.

Powering on and off

The Cisco MDS 8Gb Fabric Switch power is provided by the enclosure. Use the OA to power on the
switch. When the switch powers on, it runs the power on self-test (POST) process. POST is a system check
that is performed each time the switch is powered on, rebooted, or reset. During POST, the LEDs flash
different colors. Any errors that occur during POST are listed in the error log. The POST process can take
up to three minutes.
Use the OA to power off the switch.
NOTE:
Each time the Cisco MDS 8Gb Fabric Switch is powered on, its settings are restored to the
startup configuration.

POST steps

The success or failure results of the diagnostic tests that run during POST is monitored through the error log
or the CLI.
POST includes the following steps:
Preliminary POST diagnostics are run
Operating system is initialized
Hardware is initialized
Diagnostic tests are run on several functions, including circuitry, port functionality, memory, statistics
counters, and serialization

Interpreting POST results

To determine if POST completed successfully and if any errors were detected:
1.
Verify that the switch LEDs indicate all components are healthy. See
interpretation of LED patterns.
2.
Verify that the switch prompt appears on the terminal of a computer workstation connected to the
switch. If there is no switch prompt when POST completes, press Enter. If the switch prompt still does
not appear, try opening another telnet session or another management tool. If this is not successful, the
switch did not successfully complete POST. Contact HP.
Cisco MDS 8Gb Fabric Switch for HP BladeSystem c-Class User Guide
Table 4
for a description and
23