Weight and physical dimensions
Table 7
lists physical properties.
Table 7
Physical dimensions
Dimension
Height
Width
Depth
Weight
Environmental requirements
To ensure proper operation, the switch must not be subjected to environmental conditions beyond those
for which it was tested. The ranges specified in
both operating and non-operating conditions.
Table 8
Environmental requirements
Condition
Ambient temperature
Humidity
Altitude
Shock
Vibration
Airflow
Supported SFPs
Do not use unsupported SFPs; they can affect switch operability. They may not fit correctly and may void
your warranty. See
For a complete list of supported devices, see the HP StorageWorks Single Point of Connectivity
Knowledge (SPOCK) website at
http://www.hp.com/storage/spock
You must sign up for an HP Passport to be granted access.
Supported HBAs
For a list of HBAs that have been tested and are known to work with the SAN switches, see the HP
StorageWorks Single Point of Connectivity Knowledge (SPOCK) website at
http://www.hp.com/storage/spock.
You must sign up for an HP Passport to be granted access.
32
A Technical Specifications
Measurement
29.3 mm (1.15 in)
208 mm (8.19 in)
280 mm (1 1.02 in)
1.27 kg (2.8 lb)
Acceptable range during operation Acceptable range during
104°F/40°C at sea level, derated
34°F/1°C per 1000 ft above sea
level
5% to 90% relative humidity,
non-condensing
0 to 10,000 ft (3 km) above sea
level
40 G, 2mS duration
0.5 G, 10 to 500 Hz
47 cubic ft per minute
"Optional
hardware" on page 10 for a list of supported SFPs.
Table 8
on page 32 list the acceptable environment for
non-operation
-40°F/-40°C to 58°F/70°C with
maximum rate of change of
68°F/20°C /hr
50% to 80% relative humidity,
non-condensing
0 to 40,000 ft (12 km) above sea
level
140 G, 2mS duration
2.0 G, 5 to 500 Hz
None required