Diagnosing Problems

Switch Connections

Bad or Damaged Cable

Always examine the cable for marginal damage or failure. A cable might be just good enough to connect
at the physical layer, but it could corrupt packets as a result of subtle damage to the wiring or connectors.
You can identify this situation because the port has many packet errors or the port constantly flaps (loses
and regains link).

Ethernet and Fiber Cables

Make sure that you have the correct cable:

Link Status

Verify that both sides have a link. A broken wire or a shut-down port can cause one side to show a link
even though the other side does not have a link.
A port LED that is on does not guarantee that the cable is functional. It might have encountered physical
stress, causing it to function at a marginal level. If the port LED does not turn on:
Catalyst 3850 Switch Hardware Installation Guide
6-2
Exchange the copper or fiber-optic cable with a known good cable.
Look for broken or missing pins on cable connectors.
Rule out any bad patch panel connections or media convertors between the source and destination.
If possible, bypass the patch panel or eliminate media convertors (fiber-optic-to-copper).
Try the cable in another port to see if the problem follows the cable.
For Catalyst 3850 switch StackWise cable, remove and inspect the cable and StackWise port for bent
pins or damaged connectors. If the StackWise cable is bad, replace it with a known good cable.
For Ethernet, use Category 3 copper cable for 10 Mbps UTP connections. Use either Category 5,
Category 5e, or Category 6 UTP for 10/100 or 10/100/1000 Mbps connections.
Verify that you have the correct fiber-optic cable for the distance (100 meters or less) and port type.
Make sure that the connected device ports match and use the same type encoding, optical frequency,
and fiber type. For more information about cabling, see the
Specifications" section on page
Determine if a copper crossover cable was used when a straight-through was required, or the
reverse. Enable auto-MDIX on the switch, or replace the cable. See
Ethernet cables.
Connect the cable from the switch to a known good device.
Make sure that both ends of the cable are connected to the correct ports.
Verify that both devices have power.
Verify that you are using the correct cable type. See
Specifications"
for more information.
Look for loose connections. Sometimes a cable appears to be seated but is not. Disconnect the cable
and then reconnect it.
B-5.
Appendix B, "Connector and Cable
Chapter 6
Troubleshooting
"SFP and SFP+ Module Cable
Table 2-2
for recommended
OL-26779-02