Environmental Specifications
Environmental Specifications
Table A-2
Table A-2
Description
Temperature, operating
Temperature, non-operating
Humidity, non-operating
Altitude
Power Specifications
Table A-3
Table A-3
Description
AC input voltage
Low AC input voltage
(limited to 800W system configurations)
AC input frequency
Maximum AC-input current
Maximum output power for each power
supply
Power supply output voltage
You can get more specific power information for your exact server configuration by using the Cisco UCS
Power Calculator:
http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/
Cisco UCS C460 Server Installation and Service Guide
A-2
lists the environmental specifications for the server.
Environmental Specifications
lists the specifications for each power supply.
Power Supply Specifications
Appendix A
Specification
10ºC to 35ºC (50ºF to 95ºF)
-40ºC to 70ºC (-40ºF to 158ºF)
95%, non-condensing at temperatures of
25ºC (77ºF) to 30ºC (86ºF)
-30m to 1500m (-100ft to 5000ft)
Specification
200 to 240 VAC nominal (Range: 180 to 264 VAC)
100 to 120 VAC nominal (Range: 90 to 132 VAC)
50 to 60 Hz nominal (Range: 47 to 63 Hz)
10A
1200 W (up to two power supplies can be installed)
Main power: 12 VDC
Standby power: 12 VDC
Server Specifications
OL-22326-01