network-clock revertive

To configure the clock-source as revertive, use the network-clock revertive command. Use the no form
of the command to remove the configuration.
Command Default
The default value is non-revertive.
Command Modes
Global configuration
Command History
Release
15.1(2)SNG
Usage Guidelines
T he network-clock revertive command specifies whether or not the clock source is revertive. Clock
sources with the same priority are always non-revertive. The default value is non-revertive.
In non-revertive switching, a switch to an alternate reference is maintained even after the original
reference recovers from the failure that caused the switch. In revertive switching, the clock switches back
to the original reference after that reference recovers from the failure, independent of the condition of
the alternate reference.
Examples
This example shows how to make the clock-source revertive:
Router(config)#[no] network-clock revertive
Related Commands
Command
network-clock
input-source
OL-26031-07
network-clock revertive
no network-clock revertive
Modification
This command was introduced.
Description
Configures a clock source line interface, an external timing input interface,
GPS interface, or a packet-based timing recovered clock as the input clock
for the system.