Single Zone Standard Unit Specifi Cations - LG LS091HSV3 Installation Manual

Single zone high efficiency, standard, extended pipe, and mega wall mounted
Hide thumbs Also See for LS091HSV3:
Table of Contents

Advertisement

Table 2: Single Zone Standard Unit Specifications
Type
System Model Number (IDU/ODU)
Nominal Cooling Capacity (Btu/h)
Cooling Power Input
(kW)
1
Nominal Heating Capacity (Btu/h)
Heating Power Input
(kW)
1
COP
EER
SEER
HSPF
Power Supply (V/Hz/Ø)
Outdoor Unit Operating Range
Cooling (°F DB)
Heating (°F WB)
Indoor Unit Operating Range
Cooling (°F)
Heating (°F)
Unit Data
Refrigerant Type
2
Refrigerant Control
IDU Sound Pressure
dB(A) (H/M/L)
3
ODU Sound Pressure
dB(A)
3
Power/Communication Cable
AWG)
IDU Net/Shipping Weight (lbs)
ODU Net/Shipping Weight (lbs)
Compressor
Compressor Type (Qty)
Fan
IDU Type (Qty)
ODU Type (Qty)
Motor/Drive
Airflow Rate
IDU Max/H/M/L (CFM)
ODU Max (CFM)
EEV: Electronic Expansion Valve
IDU: Indoor Unit
Power Input is rated at high speed.
1
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy
2
R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608
of CAA.
Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.
3
All power/communication cables to be minimum 18 AWG, 4-conductor, stranded, shielded and must
4
comply with applicable and national code.
LS307HV3 (LSN307HV3/LSU307HV3)
1
(No. x
4
ODU: Outdoor Unit
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
Single Zone Standard Unit Specifications
Single Zone Standard Units
30,000
3.0
32,000
3.1
3.0
10.0
18.0
9.5
208-230/60/1
14-118
-4-75
64-90
60-86
R410A
EEV
49/44/39
55
4 x 18
36/42
128/137
Twin Rotary (1)
Cross Flow
Propeller
Brushless Digitally Controlled/Direct
883/770/629/424
2,119
Power wiring is field supplied and must comply with the applicable local and national codes
This unit comes with a dry helium charge.
This data is rated 0 ft above sea level with 24.6 of refrigerant line per indoor unit and a 0 ft level
difference outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 59ºF wet
bulb (WB) and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
general data
LS360HV3 (LSN360HV3/LSU360HV3)
33,000
4.0
35,200
3.8
2.7
8.2
16.1
9.9
208-230/60/1
14-118
-4-75
64-90
60-86
R410A
EEV
49/44/39
55
4 x 18
36/42
128/137
Twin Rotary (1)
Cross Flow
Propeller
883/795/629/424
2,119
11