Troubleshooting
Alarms
An alarm (warning message) appears in the status display
area when an operation is attempted which is inappropriate
for the settings on this unit or the state of a media. Both the
alarm message and the action to take to resolve the
problem appear on the video monitor screen or on a PC
monitor connected to the MONITOR connector.
When the unit is powered on
Alarm message in status
display area
ILL. SETUP!
Exchg batt!
Update Err!
ADJ. Mode!
PSU detect
DVB-ASI detect
Alarm message in video monitor screen Description/action
INVALID SETTINGS SELECTED IN
SETUP MENU.
SET ITEMS IN THE SETUP MENU TO
THE APPROPRIATE VALUES.
CONTACT SERVICE IF THIS ALARM
APPEARS AGAIN AFTER ABOVE
PROCEDURE.
BATTERY NEEDS REPLACING.
PLEASE CONTACT SERVICE.
RUN SOFTWARE UPDATE PROGRAM.
–
OPTIONAL REDUNDANT POWER
SUPPLY UNIT HAS BEEN
DETECTED.PLEASE CHECK AND SET
MAINTENANCE MENU ITEM M22.
OPTIONAL DVB-ASI I/O UNIT HAS BEEN
DETECTED.PLEASE CHECK AND SET
MAINTENANCE MENU ITEM M22.
Example alarm in status display area
Example alarm in video monitor screen
When an alarm is displayed, remove the alarm cause by
following the action to take. If the alarm display does not
disappear, contact your Sony service or sales
representative.
Reset the settings in the setup menu (see page 78).
If the same message appears after you reset the
settings, contact your Sony service or sales
representative.
The battery of the internal clock is exhausted.
Contact your Sony service or sales representative.
The software update is not properly performed.
Update the software version again. If the same
message appears after you update the software
version, contact your Sony service or sales
representative.
This appears when the unit is in adjustment mode.
Contact your Sony service representative.
An optional power supply unit has been detected.
Set the maintenance menu item M22: OPTION
SETTING.
An optional DVB-ASI I/O unit has been detected.
Set the maintenance menu item M22: OPTION
SETTING.
101