Installing or Replacing Server Components

Special Considerations for Cisco UCS Fusion ioDrive3 Storage Accelerator Cards

Table 3-7
Table 3-7
Cisco UCS C220 M4 Requirements for Fusion ioDrive3 Cards
Card
Cisco UCS 5800 GB MLC Fusion ioDrive3
UCSC-F-FIO-5800M=
Cisco UCS 2900 GB MLC Fusion ioDrive3
UCSC-F-FIO-2900M=
Cisco UCS 1450 GB MLC Fusion ioDrive3
UCSC-F-FIO-1450M=
Cisco UCS 1150 GB MLC Fusion ioDrive3
UCSC-F-FIO-1150M=
1. All slots can be enabled to provide more than the default 25 W power draw for higher performance on some cards. See
Fusion ioDrive3 Cards, page
2. A rear-panel tab adapter is required to fit the half-height cards in full-height slots.
Enabling Higher Power-Draw for Fusion ioDrive3 Cards
Some Fusion ioDrive3 accelerator cards such as the 5800 GB card draw 25 W by default but can achieve
higher performance when the PCIe slot is configured to provide more than 25 W for the device.
PCIe slots that can be configured to support more than 25 W power draw: All.
All slots can support the higher device power draw of 55 W (75 W maximum) when configured with the
override parameter in the IO Accelerator VSL software.
See the Cisco UCS power calculator to determine the total power draw for your exact server
Note
configuration:
http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/
The override parameter in the IO Accelerator VSL software (in the
/usr/modprove.d/iomemory-vsl.conf
more than 25 W from the PCIe slot. The parameter is enabled by device, by using the device serial
numbers.
The override parameter is a setting for the IO Accelerator VSL software by server and is not stored in
Note
the device. When moved to a new server, the device defaults to the 25 W power limit until an external
power cable is added or the override parameter is enabled for that device in the new server.
Determine the serial number of the installed Fusion device by using the
Step 1
Accelerator VSL software. Sample output is shown here:
fio-status
Adapter: Dual Controller Adapter
Cisco UCS C220 M4 Server Installation and Service Guide
3-42
describes the requirements for the supported Cisco UCS Fusion ioDrive3 cards.
Maximum
Number of Cards
Supported
1
2
2
2
3-42.
Slots That
Slots That
Support >25W
Support These
Power
Cards
Override
1
PCIE 1
All
PCIE 1
Not
applicable
PCIE 2
PCIE 1
Not
applicable
PCIE 2
PCIE 1
Not
applicable
PCIE 2
file) overrides the setting that prevents devices from drawing
Chapter 3
Maintaining the Server
Minimum
Card Height
Cisco IMC
(rear-panel
Firmware
tab)
2.0(2)
Full height
2.0(2)
Half height
2.0(2)
Half height
2.0(2)
Half height
Enabling Higher Power-Draw for
command in the IO
fio-status
OL-32473-01
2

Hide quick links: