Sign In
Upload
Manuals
Brands
Honeywell Manuals
Smoke Alarm
MS-9200UDLSE
Honeywell MS-9200UDLSE Control Panel Manuals
Manuals and User Guides for Honeywell MS-9200UDLSE Control Panel. We have
3
Honeywell MS-9200UDLSE Control Panel manuals available for free PDF download: Manual, Wiring Manual
Honeywell MS-9200UDLSE Manual (188 pages)
Fire Alarm Control Panel
Brand:
Honeywell
| Category:
Control Panel
| Size: 2.55 MB
Table of Contents
Table of Contents
5
SECTION 1: Product Description
12
Features and Options
12
Specifications
13
1: Current Availability
15
Controls and Indicators
16
Circuits
17
Digital Alarm Communicator/Transmitter
17
Components
18
1: Intelligent Addressable Detectors: Newer Series
18
2: Intelligent Addressable Modules: Newer Series
19
3: 300 Series Intelligent Addressable Devices
19
4: Addressable Device Accessories
19
Optional Modules
20
Accessories
20
1: PK-CD Programming Utility
20
2: Dress Panel
20
3: Battery Box
21
4: Battery Charger
21
CHG-120F Battery Charger
21
5: Annunciators
22
Getting Started
23
Telephone Requirements and Warnings
24
1: Telephone Circuitry
24
2: Digital Communicator
24
3: Telephone Company Rights and Warnings
25
4: for Canadian Applications
26
SECTION 2: Installation
27
Mounting Backbox
27
Mounting Transformer
28
Power
31
1: AC Power and Earth Ground Connection
31
2: Battery Power
31
3: Special Application DC Power Output Connection
31
Relays
32
Notification Appliance Circuits
32
1: Configuring Nacs
33
2: Style y (Class B) NAC Wiring
33
3: Style Z (Class A) NAC Wiring
34
Remote Synchronization Output
34
UL Power-Limited Wiring Requirements
35
Digital Communicator
36
Optional Module Installation
37
1: 4XTMF Transmitter Module Installation
38
2: Printer/Pc
40
3: Digital Communicator and Annunciators
41
ACM-8RF Relay Control Module
41
ACS and AFM Series Annunciators
41
SECTION 3: Programming
42
Programming Data Entry
42
User Programming
43
Initial Power-Up
44
Programming Screens Description
44
Programming and Passwords
44
Master Programming Level
46
1=Autoprogram
47
2: Point Program
48
Detector Programming
48
Add Detector
48
Delete Detector
49
Edit Detector
49
Module Programming
58
Add Module
58
Delete Module
59
Edit Module Screen for Monitor Module
59
Edit Module Screen for Control Modules
68
3=Zone Setup
75
Enable
75
Disable
76
Zone 97, 98 and 99
76
Zones Installed
77
Zones Enabled
77
Zones Disabled
77
Zone Type
78
Zones Available
79
4: Loop Setup
79
Style
79
Loop Protocol
79
5: System Setup
80
Trouble Reminder
81
Banner
81
Time-Date
82
Time
82
Date
83
Clock Format
83
Daylight Savings Time
83
Timers
84
PAS (Positive Alarm Sequence) Delay
84
Presignal Delay
85
Waterflow Delay
85
AC Loss Delay
86
NAC (Notification Appliance Circuit)
86
Enabled
87
Type
88
Silenceable
88
Auto Silence
89
Coding (Only for Nacs Not Programmed as Sync Strobe Type)
89
Zone
91
Silence Inhibited
91
Sync Type
91
Relays
92
Canadian Option
93
Waterflow Silenceable
93
6: Verify Loop
93
7: History
94
View Events
94
Erase History
94
8: Walktest
95
9: Option Modules
96
Annunciators/Udact
96
Onboard DACT
97
Onboard DACT Enable
97
Primary Phone
98
Secondary Phone
98
Service Terminal
99
Central Station
101
Trouble Call Limit (Dialer Runaway Prevention)
102
Manual Dial Mode
114
Printer/Pc
115
10: Password Change
116
11: Clear Program
117
12: Program Check
118
Maintenance Programming Level
120
1: Disable Point
121
2=History
122
3: Program Check
123
4: Walktest
124
5: System
124
6: Zone Setup
126
SECTION 4: Operating Instructions
128
Panel Control Buttons
128
1: Acknowledge/Step
128
2: Alarm Silence
128
3: Drill/Hold 2 Sec
128
4: Reset
128
LED Indicators
129
Normal Operation
130
Trouble Operation
130
Alarm Operation
132
Supervisory Operation
133
Process Monitor Operation
134
Hazard/Tornado Condition Operation
134
Medical Alert Condition Operation
134
NAC Operation
134
Programmed Zone Operation
135
Disable/Enable Operation
135
Waterflow Circuits Operation
135
Detector Functions
135
Time Functions: Real-Time Clock
135
Synchronized NAC Operation
136
Coded Operation
136
Presignal
136
Positive Alarm Sequence
137
Special System Timers
138
1: Silence Inhibit Timer
138
2: Autosilence Timer
138
3: Trouble Reminder
138
4: Waterflow Retard Timer
138
5: Alarm Verification (None or One Minute)
139
Walktest
139
Read Status
140
1: System Point
141
2: Zones
142
3: Power
143
4: Trouble Reminder
144
5: Timers
144
6: Nac
145
7: Relays
145
8: Program Check
146
9: History
146
10: Annunciators
147
11: Phone Line
147
12: Central Station
148
13: Service Terminal
149
14: Printer/Pc
149
15: Print
150
16: Time-Date
152
SECTION 5: Central Station Communications
153
Transmittal Priorities
156
SECTION 6: Remote Site Upload/Download
158
Downloading Program
158
1: Security Features
159
Downloading Initiated at a Service Terminal
161
Uploading Initiated at a Service Terminal
162
SECTION 7: Power Supply Calculations
163
Overview
163
Calculating the AC Branch Circuit
163
Calculating the System Current Draw
164
1: Overview
164
2: How to Use Table 7.3 on Page 165 to Calculate System Current Draw
164
Calculating the Battery Size
166
1: NFPA Battery Requirements
166
2: Selecting and Locating Batteries
166
APPENDIX A: Software Zones
167
A.1: Correlations
167
APPENDIX B: Default Programming
173
APPENDIX C: NFPA Standard-Specific Requirements
174
APPENDIX D: Wire Requirements
178
APPENDIX E: HVAC Control
179
E.1: Control Module Operation
179
E.1.1: Hvac Shutdn
179
E.2: Monitor Module Operation
179
E.2.1: Hvac Restart
179
E.2.2: Hvac Ovrride
180
Advertisement
Honeywell MS-9200UDLSE Wiring Manual (80 pages)
Intelligent Control Panel, SLC
Brand:
Honeywell
| Category:
Control Panel
| Size: 3.06 MB
Table of Contents
Table of Contents
5
Section 1: Introduction
8
Scope
8
1: Reference Documentation
8
Overview
10
Polling Protocols
10
1: Available Protocols
10
2: Protocol Use
10
Devices
10
1: Isolator Modules
10
2: Monitor Modules
10
3: Control Modules
11
4: Relay Modules
11
5: Multiple Input/Output Modules
11
6: Intelligent Detectors
11
Manual Pull Station
12
8: Wireless Gateway
12
9: 300 Series Addressable Devices
12
10: 900 Series Addressable Devices
12
SLC Capacity
12
SLC Performance
12
Surge Suppression
13
LED Operation
13
Section 2: Wiring Requirements
14
Wire Sizing
14
1: CLIP (Classic Loop Interface Protocol) Mode
14
2: Litespeed Mode
14
Measuring Resistance & Length
14
1: Two-Wire SLC - Class B
14
2: Four-Wire SLC Class a and Class X
15
Shield Wire Termination
16
Control Panel Terminal Blocks
17
1: Ms-9200
17
2: Ms-9600, Ms-9600Ls, & Ms-9600Udls
17
3: MS-9200UDLS (Software Version 3.0)
18
4: MS-9200UD & MS-9200UDLS (Versions 1 and 2)
18
5: Ms-9050Ud
18
6: Es-50X
19
7: Es-200X
19
Section 3: SLC Circuits Without Isolators
20
Overview
20
NFPA Class B SLC
20
NFPA Class a SLC
21
Section 4: SLC Circuits with Isolators
22
Fault Isolator Devices
22
1: Isolating an SLC Branch
22
2: Wiring an Isolator Module
22
NFPA Class B SLC Using Isolator Modules
24
NFPA Class a SLC Using Isolator Modules
26
NFPA Class X SLC Using Isolator Modules
27
Section 5: Monitor Modules
28
Descriptions
28
1: Addressable Monitor Modules
28
2: Zone Interface Modules
30
3: Dual Monitor Module
32
4: Mini Monitor Module
32
Installation
32
1: Setting an SLC Address for a Single Point Module
33
2: Setting an SLC Address for a Multi-Point Module
33
MMF-300 Wiring Diagrams
34
1: Wiring a NFPA Class B IDC with an MMF-300
34
2: Wiring a NFPA Class a IDC with an MMF-300
35
3: MMF-300 Wiring for Emergency Alarm System Applications
36
MMF-300-10 Wiring Diagrams
37
1: Wiring a NFPA Class B IDC with an MMF-300-10
37
2: Wiring a NFPA Class a IDC with an MMF-300-10
38
MDF-300 Wiring Diagrams
39
1: Wiring a NFPA Class B IDC with an MDF-300
39
MMF-302 Wiring Diagrams
40
1: Wiring a NFPA Class B IDC with an MMF-302
40
2: Wiring a NFPA Class a IDC with an MMF-302
41
MMF-302-6 Wiring Diagrams
42
1: Wiring a NFPA Class B IDC with an MMF-302-6
42
2: Wiring a NFPA Class a IDC with an MMF-302-6
43
Section 6: Control Modules
44
Description
44
CMF-300 Installation
44
1: Setting an SLC Address for a CMF-300 Module
44
2: Wiring a Notification Appliance Circuit (NAC) with a CMF-300
44
Wiring a CMF-300 Module
44
1: Wiring a Class B NAC (Two-Wire) with Addressable Control Modules
44
2: Wiring a Class a NAC (Four-Wire) with Addressable Control Modules
45
CMF-300-6 Installation
46
1: Cabinet Installation
46
2: Setting an SLC Address for an CMF-300-6 Module
46
3: Setting Nacs as Class B or Class a
46
4: Disabling Unused Module Addresses
46
5: Short Circuit Protection
46
6: Features Not Supported
46
7: Circuit Board Information
47
Wiring a CMF-300-6 Module
48
1: Wiring a Class B NAC (Two-Wire)
48
2: Wiring a Class a NAC (Four-Wire)
49
Section 7: Relay Modules
50
Description
50
CRF-300 Installation & Wiring
50
1: Setting an SLC Address for a CRF-300 Module
50
2: Wiring a CRF-300 Module (Form-C Relay)
50
CRF-300-6 Circuit Board Information
51
CRF-300-6 Installation & Wiring
52
1: Cabinet Installation
52
2: Setting an SLC Address for a CRF-300-6 Module
52
3: Disabling Unused Module Addresses
52
4: Wiring a CRF-300-6 Module (Form-C Relay)
52
Section 8: Multiple Input/Output Modules
53
Description
53
CDRM-300 Installation & Wiring
53
1: Setting an SLC Address for a CDRM-300 Module
53
2: Wiring a CDRM-300 Module (Form-C Relay)
53
Section 9: Intelligent Detector Bases and Wireless Gateway
54
Description
54
Setting the Detector Address
54
Wiring a Detector Base
55
Wiring an Isolator Base
56
Wiring a Relay Base
56
Wiring a Sounder Base
57
Wiring the W-GATE
57
1: SLC Connections
58
2: W-GATE Powered by the SLC
58
3: W-GATE Powered by a Regulated, External +24VDC Power Source
59
Section 10: Addressable Beam Detectors
60
Description
60
Installation and Wiring
60
1: Setting an SLC Address for a Beam Detector
60
2: Wiring a Beam Detector
60
Section 11: Addressable Manual Pull Station
62
Description
62
Installation
62
1: Setting an SLC Address
62
2: Wiring a Manual Pull Station
62
Appendix A: Power Considerations
63
A.1: Supplying Power to 24 VDC Detectors and Nacs
63
A.1.1: Resistance and Size
63
A.2: Supervising 24 VDC Power
64
Appendix B: Surge Suppression
65
B.1: Introduction
65
B.2: Installation
65
B.2.1: Wiring Diagram for MS-9200
66
B.2.2: Wiring Diagram for MS-9600, MS-9600LS, MS-9600UDLS, MS-9200UD, MS-9200UDLS, and MS-9050UD
67
B.2.3: Wiring Diagram for ES-50X and ES-200X
68
Appendix C: Terminal Conversion Charts for New & Legacy Devices
69
C.1: Crf-300
69
C.2: CMF-300 and MMF-302
69
C.3: Mmf-300
70
C.4: Mdf-300
71
Appendix D: Intelligent Detector Base Layouts for Legacy Devices
72
D.1: B350LP or B501 Detector Base
72
D.2: B224BI Isolator Base
73
D.3: B224RB Relay Base
73
D.4: B501BH(-2) and B501BHT(-2) Sounder Bases
74
Appendix E: Canadian Versions of SLC Devices
75
Index
77
Honeywell MS-9200UDLSE Manual (6 pages)
Intelligent Addressable FACP with Built-In Communicator
Brand:
Honeywell
| Category:
Industrial Equipment
| Size: 0.47 MB
Advertisement
Advertisement
Related Products
Honeywell MS-9200UDLS
Honeywell MS-5UD Series
Honeywell MS-10UD Series
Honeywell LT-200 MI-FL20 Series
Honeywell LT-200 MI-FL2011EI-HS
Honeywell LT-200 MI-FL2012EI-HS
Honeywell LT-200 MI-FL2022EI-HS
Honeywell Fire-Lite Alarms MS-9200
Honeywell Fire-Lite Alarms MS-9200E
Honeywell Fire-Lite Alarms MS-9200UD
Honeywell Categories
Thermostat
Controller
Control Unit
Security Camera
Accessories
More Honeywell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL