Table of Contents
Fire Alarm System Limitations
2
Installation Precautions
3
Table of Contents
4
Product Description
12
Product Features
13
Specifications
14
Controls and Indicators
16
Digital Alarm Communicator/Transmitter
17
Components
18
Optional Modules and Accessories
18
Telephone Requirements and Warnings
20
Telephone Circuitry
20
Digital Communicator
20
Telephone Company Rights and Warnings
21
For Canadian Applications
22
Installation
23
Backbox Mounting
23
Operating Power
26
Input Circuits
27
Output Circuits
29
Notification Appliance Circuits
29
Special Application DC Power Output Connections
30
Relays - Programmable
30
Remote Synchronization Output
31
Power-Limited Wiring Requirements
32
Digital Communicator
33
Installation of Optional Modules
34
CAC-5X Class a Converter Module
34
Installation
34
Wiring Nacs and Idcs for Class a
35
4XTMF Option Module
36
4XTMF Transmitter Module Installation
37
ANN-BUS Devices
38
ANN-BUS Wiring
38
Calculating Wiring Distance for ANN-BUS Modules
38
Wiring Configuration
40
Powering ANN-BUS Devices from Auxiliary Power Supply
41
ANN-BUS Device Addressing
41
Remote Fire Annunciator
42
Specifications
42
Installation
42
Mounting
42
Opening/Closing Annunciator
42
Wiring ANN-80 to FACP
43
ANN-S/PG Serial/Parallel Printer Interface Installation
45
PRN-6F Printer Installation
45
Specifications
45
Connecting PRN-6F Printer
46
Setting Printer Options
46
ANN-I/O LED Driver Module
47
ANN-I/O Board Layout
47
Specifications
47
ANN-I/O Connection to FACP
48
ANN-I/O Module LED Wiring
49
ANN-LED Annunciator Module
50
ANN-LED Board Layout
50
Mounting/Installation
50
Specifications
50
ANN-LED Connection to FACP
51
ANN-RLY Board Layout
52
ANN-RLY Relay Module
52
Mounting/Installation
52
Specifications
52
ANN-RLY Connection to FACP
53
ANN-BUS Audio Panel
54
Programming
55
User Programming
55
Initial Power-Up
56
Programming Screens Description
56
Programming and Passwords
57
Master Programming Level
58
Input Zones
59
Zone Type
60
NAC (Notification Appliance Circuit)
67
Enabled
68
NAC Coding
68
Synchronized NAC Operation
69
Two Stage Operation
69
Silence
70
Auto Silence
71
Relays
71
Silence Inhibited
71
Relay Type
72
System Setup
73
PAS (Positive Alarm Sequence) Delay
74
Presignal Delay
74
Timers
74
AC Loss Delay
75
Waterflow Delay
75
Banner
76
Time
77
Time-Date
77
Clock Format
78
Date
78
Daylight Savings Time
78
Canadian Option
79
Charger Disable
79
Option Modules
79
Trouble Reminder
79
Ann-Bus
80
ANN-BUS Enabled
80
BUS Modules
80
Auto-Configure
81
ANN-S/PG Options Screen
82
ANN-I/O LED Zone Assignments
83
Options Screen
84
ANN-RLY Options Screen
85
ANN-AUDIO Options Screen
86
Onboard DACT
87
Primary Phone
87
Secondary Phone
87
Central Station
88
Test Time Interval
89
Account Code
90
Hour Test Time
90
Event Codes
91
Service Terminal
99
History
100
Supervised Phone Line
100
Erase History
101
View Events
101
Walktest
102
Clear Program
103
Password Change
103
Maintenance Programming Level
104
History
105
Input Zones - Enable/Disable
105
Walktest
106
Time-Date
107
Operating Instructions
108
Panel Control Buttons
108
Acknowledge/Step
108
Alarm Silenced
108
Drill/Hold 2 Sec
108
Reset
108
LED Indicators
109
Normal Operation
109
Trouble Operation
110
Alarm Operation
111
Supervisory Operation
112
Process Monitor Operation
113
Hazard/Tornado Condition Operation
113
Medical Alert Condition Operation
113
Disable/Enable Operation
114
Waterflow Circuits Operation
114
Detector Functions
114
Time Functions: Real-Time Clock
114
Coded Operation
114
Presignal
115
Positive Alarm Sequence
115
Special System Timers
116
Silence Inhibit Timer
116
Autosilence Timer
116
Trouble Reminder
116
Waterflow Retard Timer
116
Alarm Verification (None or One Minute)
117
Walktest
117
Read Status
118
Input Zones
119
Nac
119
Relays
120
System Settings
120
Timers
121
Daylight Savings
121
History
122
Print
122
Ann-Bus
123
Central Station
124
Phone Line 2
125
Service Terminal
125
Central Station Communications
126
Transmittal Priorities
127
Local/Remote Site Upload/Download
129
Remote Download
129
Transferring a Program
131
Security Features
131
Power Supply Calculations
133
Overview
133
Calculating the AC Branch Circuit
133
Calculating the System Current Draw
134
How to Use Table 7-3 on Page 134 to Calculate System Current Draw
134
Overview
134
Calculating the Battery Size
136
NFPA Battery Requirements
136
Selecting and Locating Batteries
136
Ademco Contact ID Format Event Code Descriptions
137
Transmission Format between DACT and Receiver
137
Ademco Contact ID Typical Printout
137
NFPA Standard-Specific Requirements
142
Central Station/Remote Station Transmitter: Connection to FACP Dry Contacts
148
FACP with Keltron
149
Wire Requirements
150
MS-5UD-3(E) & MS-10UD-3(E) NAC Wiring
151
MS-5UD-7(C/E) & MS-10UD-7(C/E) NAC Wiring
151
Limited Warranty
159
Advertisement
Honeywell MS-5UD Series Manual (136 pages)
Fire Alarm Control Panels
Brand:
Honeywell
| Category:
Control Panel
| Size: 2.85 MB
Table of Contents
Table of Contents
5
Section 1: Product Description
12
Product Features
12
Specifications
13
Controls and Indicators
17
Digital Alarm Communicator/Transmitter
17
Components
18
Optional Modules and Accessories
18
Telephone Requirements and Warnings
19
1: Telephone Circuitry
19
2: Digital Communicator
19
3: Telephone Company Rights and Warnings
19
4: for Canadian Applications
20
Section 2: Installation
21
Backbox Mounting
21
Operating Power
23
Input Circuits
24
Output Circuits
26
1: Notification Appliance Circuits
26
2: Special Application DC Power Output Connections
27
3: Relays - Programmable
28
4: Remote Synchronization Output
28
Power-Limited Wiring Requirements
29
Digital Communicator
30
Installation of Optional Modules
31
1: CAC-5X Class a Converter Module
31
Installation
31
Wiring Nacs and Idcs for Class a
31
2: 4XTMF Option Module
32
4XTMF Transmitter Module Installation
33
3: ANN-SEC Option Card
34
ANN-BUS Devices
35
Guidelines
35
1: ANN-BUS Wiring
35
Calculating Wiring Distance for ANN-BUS Modules
35
Wiring Configuration
37
Powering ANN-BUS Devices from Auxiliary Power Supply
38
2: ANN-BUS Device Addressing
38
3: ANN-80(C) Remote Fire Annunciator/Indicator
38
Specifications
39
Installation
39
Opening/Closing Annunciator
39
Mounting
39
Wiring ANN-80 to FACP
40
4: ANN-S/PG Serial/Parallel Printer Interface Installation
41
Specifications
41
Printer Installation
41
PRN-6F Printer Installation
42
5: ANN-I/O LED Driver Module
43
ANN-I/O Board Layout
43
Specifications
43
ANN-I/O Connection to FACP
44
ANN-I/O Module LED Wiring
44
6: ANN-LED Annunciator Module
45
Specifications
45
Mounting/Installation
45
ANN-LED Board Layout and Connection to FACP
46
7: ANN-RLY Relay Module
46
Specifications
46
Mounting/Installation
47
ANN-RLY Board Layout and Connection to FACP
48
ANN-BUS Audio Panel
48
Section 3: Programming
50
User Programming
50
Initial Power-Up
52
Programming Screens Description
52
Programming and Passwords
52
Master Programming Level
53
1=Input Zones
53
2: NAC (Notification Appliance Circuit)
64
Enabled
64
NAC Coding
64
Silence
66
Auto Silence
66
Silence Inhibited
66
3=Relays
67
4: System Setup
67
Timers
67
Banner
69
Time-Date
69
Trouble Reminder
70
Canadian Option
70
Charger Disable
71
5: Option Modules
71
Ann-Bus
71
ANN-RLY Options Screen
74
ANN-AUDIO Options Screen
74
ANN-SEC Enable
74
Onboard DACT
75
6: History
91
View Events
91
Erase History
92
7: Walktest
92
8: Clear Program
92
Printer/Pc
93
9: Password Change
93
Maintenance Programming Level
94
1: Input Zones - Enable/Disable
94
2=History
94
3=Walktest
95
4: Time-Date
95
Section 4: Operating Instructions
96
Panel Control Buttons
96
1: Acknowledge/Step
96
2: Alarm Silenced
96
3: Drill/Hold 2 Sec
96
4: Reset
96
LED Indicators
96
Normal Operation
96
Trouble Operation
97
Alarm Operation
97
Supervisory Operation
98
Process Monitor Operation
98
Hazard/Tornado Condition Operation
99
Medical Alert Condition Operation
99
Disable/Enable Operation
99
Waterflow Circuits Operation
99
Detector Functions
99
Time Functions: Real-Time Clock
100
Coded Operation
100
Presignal
100
Positive Alarm Sequence
100
Special System Timers
100
1: Silence Inhibit Timer
100
2: Autosilence Timer
101
3: Trouble Reminder
101
4: Waterflow Retard Timer
101
5: Alarm Verification (None or One Minute)
101
Walktest
101
Read Status
102
1=Input Zones
102
2=Nac 2
102
3: Relays
103
4: System Settings
103
5: Timers
103
6: Daylight Savings
103
7: History
103
8: Print
103
9: Ann-Bus
104
10: Central Station
104
11: Phone Line
104
12: Service Terminal
105
Section 5: Central Station Communications
106
Transmittal Priorities
106
Section 6: Local/Remote Site Upload/Download
108
Remote Download
108
Transferring a Program
108
1: Security Features
109
Section 7: Power Supply Calculations
110
Overview
110
Calculating the AC Branch Circuit
110
Calculating the System Current Draw
110
2: How to Use Table 7.3 on Page 111 to Calculate System Current Draw
110
Calculating the Battery Size
112
1: NFPA Battery Requirements
112
2: Selecting and Locating Batteries
112
Appendix A: Ademco Contact ID Format Event Code Descriptions
113
A.1: Transmission Format between DACT and Receiver
113
A.2: Ademco Contact ID Typical Printout
113
Appendix B: NFPA Standard-Specific Requirements
118
B.1: Central Station/Remote Station Transmitter: Connection to FACP Dry Contacts
123
Appendix C: FACP with Keltron
124
Appendix D: Wire Requirements
125
D.1: MS-5UD-3(E) & MS-10UD-3(E) NAC Wiring
125
D.2: MS-5UD-7(C/E) & MS-10UD-7(C/E) NAC Wiring
126
Appendix E: Default Programming
127
Appendix F: Canadian Applications
128
F.1: ANN-LED Annunciator Installation for Canadian Applications
128
Index
130
Operating Instructions
133
Advertisement
Related Products
Honeywell MS-9200UDLS
Honeywell MS-9200UDLSE
Honeywell MS-10UD Series
Honeywell LT-200 MI-FL20 Series
Honeywell LT-200 MI-FL2011EI-HS
Honeywell LT-200 MI-FL2012EI-HS
Honeywell LT-200 MI-FL2022EI-HS
Honeywell Fire-Lite Alarms MS-5UD-3
Honeywell Fire-Lite Alarms MS-5UD-7
Honeywell Fire-Lite Alarms MS-5UD-7C
Honeywell Categories
Thermostat
Controller
Control Unit
Security Camera
Accessories
More Honeywell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL