IBM iSeries 870 Manuals
Manuals and User Guides for IBM iSeries 870. We have
3
IBM iSeries 870 manuals available for free PDF download: Service Manual, Hardware Problem Analysis And Isolation, Analyze Hardware Problems (System Reference Codes
IBM iSeries 870 Service Manual (622 pages)
SB2 and SB3 Hardware
Brand:
IBM
| Category:
Server
| Size: 26.33 MB
Table of Contents
Table of Contents
5
Analyze Hardware Problems
13
Remove and Replace Procedures
14
Models 270, 800, and 810 Remove and Replace Procedures
14
Models 270, 800, and 810 - Air Moving Device - B01 and B02
15
Models 270, 800, and 810 - Air Moving Device - B03
15
Models 270 and 810 - Cards (Concurrent)
16
Models 270, 800, and 810 - Cards (Dedicated)
18
Models 270, 800, and 810 - Control Panel - NB1
18
Models 270, 800, and 810 - Covers
19
Models 270, 800, and 810 - Device Board - DB1, DB2, and DB3
20
Models 270, 800, and 810 - Disk Unit (Concurrent)
20
Models 270, 800, and 810 - Disk Unit (Dedicated)
23
Memory - a through H
24
Memory on the Riser
24
Models 270, 800, and 810 - Memory
24
Models 270 and 810 - Processor - M02
25
Models 270, 800, and 810 - Power Supply - P01
25
Models 270, 800, and 810 - Power Supply - P02
25
Laser Safety Information
26
Models 270, 800, and 810 - Processor Regulator - R01
26
Models 270, 800, and 810 - Removable Media - D07 and D08
26
Models 270, 800, and 810 - System Unit Backplane - MB1
27
Models 270, 800, and 810 - Time of Day (TOD) Battery
28
Model 820 Remove and Replace Procedures
28
Model 820
29
Model 820 - Air Moving Device (AMD) - B01 through B04
29
Model 820 - Cards (Concurrent)
30
Model 820 - Cards (Dedicated)
31
Model 820 - Control Panel - NB1
32
Model 820 - Covers
33
Model 820 - Device Board - DB1 and DB2
33
Model 820 - Disk Unit (Concurrent)
33
Model 820 - Disk Unit (Dedicated)
35
Model 820 - Memory
36
Model 820 - Power Supply - P01, P02, and P03
37
Model 820 - Processor - M03
37
Model 820 - Processor Regulator - M03
37
Laser Safety Information
38
Model 820 - Removable Media - D13 and D14
38
Model 820 - System Unit Backplane (MB1) and Power Distribution Board (PB1)
38
Model 820 - Time of Day (TOD) Battery
40
Model 825 Remove and Replace Procedures
41
Model 825
41
Model 825 - Air Moving Device (AMD) - B01; B02 (Concurrent)
41
Model 825 - Cards (Concurrent)
42
Model 825 - Cards (Dedicated)
44
Model 825 - Control Panel - NB1
45
Model 825 - Covers
46
Model 825 - Device Board - DB1
46
Model 825 - Device Board - DB2, DB3, and DB4
47
Model 825 - Disk Unit (Concurrent)
47
Model 825 - Disk Unit (Dedicated)
49
Model 825 - HSL Card - MB1 and MB2
50
Model 825 - Interlock Switch
51
Model 825 - Memory - a through H
53
Model 825 - Power Cable Harness Assembly
53
Model 825 - Power Supply P01 and P02
54
Model 825 - Removable Media - D17 and D18
55
Model 825 - System Unit Backplane - CB1 and Power Bus Bar Assembly
57
Model 825 - Time of Day (TOD) Battery
61
Models 830/SB2 Remove and Replace Procedures
61
Models 830/SB2 with FC 9074 (with Single Line Cord) - AC Input/Charger (A01)
62
Model 830 with FC 9074, Model 840 with FC 9079 or FC 8079 (with Dual Line Cords) - AC Module (A01, A02)
62
Models 830/SB2 with FC 9074 - Air Moving Device - BP1 and BP2
63
Models 830/SB2 with FC 9074 - Battery (T01 through T04)
63
Models 830/SB2 with FC 9074 - Cards (Concurrent)
64
Models 830/SB2 with FC 9074 - Cards (Dedicated)
66
Models 830/SB2 with FC 9074 - Covers
70
Model 830/SB2 - Device Board (DB1 and DB2)
71
Models 830/SB2 - Device Board (DB3)
73
Disk Unit, Models 830/SB2 and 840/SB3 (Dedicated and Concurrent)
74
Models 830/SB2 with FC 9074 - System Unit Control Panel (NB1)
76
Models 830/SB2 with FC 9074 - Power Distribution Backplane (PB1)
78
Models 830/SB2 with FC 9074 - Power Supply (PP1 and PP2)
79
Model 830/SB2 - Processor Feature Codes and Ccins
80
Models 830/SB2 with FC 9074 - Removable Media (D41 and D42)
80
Laser Safety Information
80
Models 830/SB2 with FC 9074 - System Unit Backplane (MB1)
82
Models 830/SB2 with FC 9074 - Time of Day (TOD) Battery
83
Models 830/SB2 with FC 9074 - Tower Card (CB1)
84
Models 840/SB3 Remove and Replace Procedures
85
Models 840/SB3 Processor Tower (with Non-Dual Line Cords) - AC Box (A01)
86
Models 840/SB3 Processor Tower (with Dual Line Cords) - AC Box (A01, A03) - Concurrent Maintenance
86
Model 830 with FC 9074, Model 840 with FC 9079 or FC 8079 (with Dual Line Cords) - AC Module (A01, A02)
86
Models 840/SB3 Processor Tower (with Dual Line Cords) - Concurrent Maintenance Adapter Card (A02)
87
Models 840/SB3 Processor Tower - Air Moving Device (B01, B02, B03, and B04)
87
Model 840/SB3 System Unit - Battery Pack (T01)
88
Models 840/SB3, FC 8079-001 (Lower Half), FC 9079 Cards (Concurrent)
88
Models 840/SB3, FC 8079-001 (Lower Half), FC 9079 Cards (Dedicated)
90
Models 840/SB3 System Unit - Charger (G01)
92
Models 840/SB3 - Covers
92
Model 840/SB3 Processor Tower, FC 8079 (Lower Half), and FC 9079 - Control Panel (NB1)
92
Disk Unit, Models 830/SB2 and 840/SB3 (Dedicated and Concurrent)
94
Models 840 or SB3 External Battery Power Unit
97
Models 840/SB3 System Unit - Power Subframe Assembly (PB1)
97
Models 840/SB3 Processor Tower - Power Supply (PS) (P01 through P06)
98
FC 5074, FC 5079, FC 9079 - Removable Media - D41 and D42
99
Models 840/SB3 System Unit - SPCN Card (R21)
101
Models 840/SB3 - System Unit Backplane (MB1) and Regulator Board (RB1)
102
Models 840/SB3 (FC 9079) - Time of Day (TOD) Battery
103
Models 870 and 890 Remove and Replace Procedures
104
Models 870 and 890 - Bulk Power Controller (BPC)
105
Models 870 and 890 - Bulk Power Distribution (BPD)
106
Models 870 and 890 - Bulk Power Enclosure (BPE)
107
Models 870 and 890 - Bulk Power F-Airmover (BPF)
107
Models 870 and 890 - Bulk Power Regulator (BPR)
108
Models 870 and 890 - Capacitor Books and Blanks
109
Models 870 and 890 - Covers
109
Models 870 and 890 - DC Converter Assembly (DCA)
110
Models 870 and 890 - L3 Modules
111
Models 870 and 890 - MCM Module (Processor) and Pass-Through Modules
117
Models 870 and 890 - MDA (Air Mover) Controller
123
Models 870 and 890 - Memory Books and Memory Blanks
124
Models 870 and 890 - Motor Scroll Assembly (MSA) Air Filters
124
Inspect the Network Interface Controller (NIC) Card
125
Models 870 and 890 - MSA (Air Mover) Enclosure
125
Models 870 and 890 - Network Interface Controller (NIC) Card
125
Models 870 and 890 - Processor MSA (Air Mover) Assembly
126
Models 870 and 890 - Supporting Information
126
Models 870 and 890 - Install the MCM/L3/Passthrough Tri-Fold Plug Map
127
Models 870 and 890 - L3 Modules - Remove the Protective Cover
127
Models 870 and 890 - MCM and Pass-Through Module - Remove Protective Covers
131
Models 870 and 890 - Remove and Replace Tools
133
Models 870 and 890 - Shorts Test Qualified Service Meters and Fail Criteria
134
Testing MCM and L3 Modules for a Short Circuit
135
Models 870 and 890 - System Clock Card
143
Models 870 and 890 - System Unit Backplane (MB1)
143
Models 870 and 890 - Unit Emergency Power off (UEPO) Card Assembly
145
Models 870 and 890 - VPD Card
146
FC 5074, FC 5079, FC 8079, FC 9074, FC 9079 Remove and Replace Procedures
148
FC 5074, FC 5079, FC 9074, FC 9079 - Air Moving Device - B01 and B02
149
FC 5074, FC 5079, FC 9079 (Single Line Cord) - AC Charger - A01
149
FC 5074, FC 5079, FC 9079 (with Dual Line Cord) - AC Module - A01 and A02
149
FC 5074, FC 5079, FC 5094, FC 5294 - Cards (Concurrent)
150
FC 5074, FC 5079, FC 9079 - Batteries - T01, T02, T03, and T04
150
FC 5074, FC 5079, FC 5094, FC 5294 - Cards (Dedicated)
152
FC 5074, FC 5079, FC 5094, FC 5294, FC 9079, FC 9094 - Covers
153
FC 5074, FC 5079, FC 9079 - Device Board - DB1 and DB2
154
FC 5074, FC 5079, FC 9079 - Device Board - DB3
156
FC 5074, FC 5079 - Disk Unit (Concurrent)
157
FC 5074, FC 5079 - Disk Unit (Dedicated)
159
FC 5074, FC 5079 - Display Panel - NB1
160
FC 5074, FC 5079, FC 9079 - Power Distribution Board - PB1
160
FC 5074, FC 5079, FC 9074, FC 9079 - Power Supply - P00, P01, P02, and P03
161
FC 5074, FC 5079, FC 9079 - Removable Media - D41 and D42
162
FC 5074, FC 5079, FC 9079 - Tower Card - CB1
164
FC 5075 Remove and Replace Procedures
167
FC 5075 - Air Moving Device - B01 and B02
167
FC 5075 - Cards (Concurrent)
168
FC 5075 - Cards (Dedicated)
169
FC 5075 - Covers
170
FC 5075 - Device Board - DB1
170
FC 5075 - Disk Unit (Concurrent)
170
FC 5075 - Disk Unit (Dedicated)
172
FC 5075 - Display Panel - NB1
173
FC 5075 - Power Distribution Board - PB1
174
FC 5075 - Power Supply - P01 and P02
174
FC 5075 - SPCN Card - SB1
174
FC 5075 - Tower Card - CB1
175
FC 5078, FC 0578 - Air Moving Device (AMD) - B01 and B02
176
FC 5078, FC 0578, FC 5088, FC 0588 Remove and Replace Procedures
176
FC 5078, FC 0578, FC 5088, FC 0588 - Air Moving Device Controller Card - BB1
177
FC 5078, FC 0578, FC 5088, FC 0588 - Cards (Concurrent)
177
FC 5078, FC 0578, FC 5088, FC 0588 - Cards (Dedicated)
179
FC 5078, FC 0578, FC 5088, FC 0588 - Covers
180
FC 5078, FC 0578, FC 5088, FC 0588 - Display Panel - NB1
180
FC 5078, FC 0578, FC 5088, FC 0588 - Power Distribution Backplane - PB1
180
FC 5078, FC 0578 - Power Supplies - P01 and P02
181
FC 5078, FC 0578, FC 5088, FC 0588 - Tower Card - CB1
181
FC 5094, FC 5294, FC 8094, FC 9094 Remove and Replace Procedures
182
FC 5094, FC 9094 (with Single Line Cord) - AC Module - A01 and A02
183
FC 5094, FC 9094 (with Dual Line Cord) - AC Module - A01 and A02
184
FC 5094, FC 9094 - Air Moving Device - B01 and B02
184
FC 8094-001 (Lower Half), FC 9094 - Cards (Concurrent)
184
FC 8094-001 (Lower Half), FC 9094 - Cards (Dedicated)
186
FC 9094 Base I/O Tower- Control Panel - NB1
187
FC 5074, FC 5079, FC 5094, FC 5294, FC 9079, FC 9094 - Covers
189
FC 5094, FC 9094 - Device Board - DB1 and DB2
190
FC 5094, FC 9094 - Device Board - DB3
191
FC 5094, FC 9094 - Disk Unit (Concurrent)
192
FC 5094, FC 9094 - Disk Unit (Dedicated)
194
FC 5094 - Display Panel - NB1
195
FC 5094, FC 9094 - Power Distribution Backplane - PB1
196
FC 5094, FC 9094 - Power Supply - P00, P01, P02, P03
197
FC 5094, FC 9094 - Removable Media - D41 and D42
198
FC 9094 - Time of Day (TOD) Battery
200
FC 5094, FC 9094 - Tower Card - CB1
201
FC 5095, FC 0595 Remove and Replace Procedures
203
FC 5095, FC 0595 - Air Moving Device - B01, B02, B03, and B04
203
FC 5095, FC 0595 - Cards (Concurrent)
204
FC 5095, FC 0595 - Cards (Dedicated)
205
FC 5095, FC 0595 - Covers
206
FC 5095, FC 0595 - Device Board - DB1 and DB2
206
FC 5095, FC 0595 - Disk Unit (Concurrent)
206
FC 5095, FC 0595 - Disk Unit (Dedicated)
208
FC 5095, FC 0595 - Display Panel - NB1
210
FC 5095, FC 0595 - Power Distribution Backplane - PB1
210
FC 5095, FC 0595 - Power Supply - P01 and P02
210
FC 5095, FC 0595 - Tower Card - CB1
211
HSL Cables - Concurrent
212
Type 2689, 2748, 2757, 2763, 2778, 2780, 2782, 2890, 2892, 4758, 5703, 5708 Cards
212
Type 2689 - Integrated Xseries Adapter (IXA)
213
Type 2748, 2757, 2763, 2778, 2780, 2782, 5703, 5708 - Cache Battery Pack
214
Separating the Removable Cache Card from the Base Card on Type 2780 Cards
219
Type 2748, 2757, 2763, 2778, 2780, 2782, 5703 - Cache Directory Card
224
Type 2890 or 2892 - Integrated Xseries Server (IXS) for Iseries
227
Type 4758 - Battery Replacement Procedure
228
Type 4758 - Cryptographic Coprocessor Disablement
229
Tape Cartridge - Manual Removal
230
Type 4685 - Tape Cartridge
230
Tape Cartridge
232
Type 6335 - 1/4 Inch Tape Cartridge
233
Optical Media (CD-ROM, DVD-ROM, and DVD-RAM) - Manual Removal
235
Part Locations and Listings
235
Locations and Addresses
236
How to Use Locations and Addresses
236
Locations - Model 270
238
Locations - Models 800 and 810
252
Model 810 System Unit Processor Features 7428, 7430
253
Models 800 and 810 System Unit (Except Processor Features 7428, 7430)
256
Locations - Model 820
260
Locations - Model 825
266
Locations - Models 830, SB2 System Unit with FC 9074 Base I/O Tower
272
Locations - Models 840, SB3 System Unit with Processor Tower and FC 9079 Base I/O Tower
282
Model 840, SB3 Processor Tower
282
Locations - Models 870 and 890 with an FC 9094 Base I/O Tower
296
Locations - Models 870 and 890
297
Locations - FC 9094 Base I/O Tower
303
Locations - FC 5074 Expansion I/O Tower
306
Locations - FC 5075 Expansion I/O Tower
311
Locations - FC 5078, 0578 Expansion I/O Unit
313
Locations - FC 5079 Expansion I/O Tower
316
Locations - FC 5088, FC 0588 Expansion I/O Unit
317
Locations - FC 5094 Expansion I/O Tower
321
Locations - FC 5095, FC 0595 Expansion I/O Tower
324
Locations - FC 5294 Expansion I/O Tower
327
Locations - FC 8079 Expansion /O Tower
327
Locations - FC 8093 Expansion I/O Tower
329
Locations - FC 8094 Expansion I/O Tower
330
Locations - Integrated Xseries Adapter Card (IXA)
330
Locations - Power Distribution Unit (PDU)
332
Locations - 2890 Integrated Xseries Server (IXS)
333
Locations - I/O Adapters
333
Addresses - Model 270
334
Locations - 2892 Integrated Xseries Server (IXS)
334
Addresses - Models 800 and 810
337
Addresses - Model 820
339
Addresses - Model 825
341
Addresses - Models 830, SB2 System Unit with FC 9074 Base I/O Tower
344
Addresses - Models 840, SB3 Processor Tower and FC 9079 Base I/O Tower
348
Addresses - Models 870 and 890 with an FC 9094 Base I/O Tower
352
Addresses - FC 5074 Expansion I/O Tower
357
Addresses - FC 5075 Expansion I/O Tower
361
Addresses - FC 5078, FC 0578 Expansion I/O Unit
363
Addresses - FC 5079 Expansion I/O Tower
364
Addresses - FC 5088, FC 0588 Expansion I/O Unit
365
Addresses - FC 5094 Expansion I/O Tower
366
Addresses - FC 5095, FC 0595 Expansion I/O Tower
372
Addresses - FC 5294 Expansion I/O Tower
375
Addresses - FC 8093 Expansion I/O Tower
375
Addresses - FC 8094 Expansion I/O Tower
375
Addresses - for External Xseries Server, Iseries Adapter - Machine Type 1519
375
Locations - FC 8079 Expansion I/O Tower
375
Memory Locations and Placement Rules
376
2884 Memory Card
376
CCIN 24A0, CCIN 244A Processor Card with DIMM Memory
376
Part Assemblies
377
How to Use this Parts Listing
377
Part Assemblies - Models 270, 800, and 810
378
Cover Assembly - Models 270, 800, and 810
379
Final Assembly - Models 270, 800, and 810
380
Control Panel Assembly - Models 270, 800, and 810
385
Cover Assembly - Models 270, 800, and 810 System Unit Expansion
386
Final Assembly - Models 270, 800, and 810 System Unit Expansion
388
Cover Assembly - Model 820
390
Part Assemblies - Model 820
390
Part Assemblies - Model 825
395
Part Assemblies - FC 0550, FC 0551, FC 0578, FC 0588, FC 0595, FC 5079, FC 5294, FC 8079, FC 8093, and FC 8094
456
FC 5074, FC 5079, FC 5094, FC 9094 Expansion I/O Tower
491
FC 5075 Expansion I/O Tower
491
FC 5078, FC 0578, FC 5088, or FC 0588 Expansion I/O Tower
491
FC 5095 or FC 0595 Expansion I/O Tower
491
Models 870 and 890 Processor Towers
491
Power and Signal Cables
491
Removable Media Address Jumper Positions
530
4685 Tape Unit
531
6321 CD-ROM Optical Unit
531
6330 DVD-RAM Optical Unit
531
6336 DVD-ROM Optical Unit
531
Type, Model, and Part Number List
532
Hardware Part Number Information
532
Power-Related Part Number Information
545
Internal and External Cables
547
Cleaning, Testing, and Miscellaneous Parts
549
Data Recovery and General Information
551
Recovery Procedures
551
Start Disk Service here
551
Dedicated Service Tools (DST) Procedures
552
Exchange a Disk Unit with Device Parity Protection
552
Exchange a Disk Unit with Mirrored Protection
552
Initialize Disk Unit and Copy to Disk
552
Resume Mirrored Protection
552
Save Data and Initialize Disk Unit
552
Verify the Repair
570
Verify Concurrent Repair
570
Verify Dedicated Repair
572
Power On/Off the System and Logical Partitions
573
Power off the System
573
Power on a Secondary Partition
573
Power on the System
573
Partition's Console
575
Power off a Secondary Partition
575
Power off a System with Multiple Logical Partitions
575
Expansion Unit Power Procedure
576
Mode Jumper Has Been Overridden
583
Set or Change the Mode of an I/O Card
583
Storage I/O Card Modes and Jumpers
583
Mode Jumper Is Missing
585
System Reference Codes (SRC) Address Formats
585
Hardware SRC Formats
589
Cryptographic I/O Processor
591
Determine if the System Has Guest Partitions
591
Determine if the System Has Logical Partitions
591
Alternate IPL Device
592
Determine the Hosting Partition of a Guest Partition
592
Determine the Load Source Disk and Alternate IPL Device
592
Determine the Release Level of a Guest Partition
592
Find the Load Source Disks on Systems with Mirrored Protection
592
Find the Load-Source Disk on Systems Without Mirrored Protection
592
What You Should Know about Load Source Disks on Systems with Mirrored Protection
592
Reclaim IOP Cache Storage
595
Forms
595
Problem Summary Form
596
Preventive Maintenance (PM)
597
Work with Electrostatic Discharge-Sensitive Parts
597
AC Power Cords - All Models
598
AC Safety Grounds
598
Covers - All Models
598
Internal Mechanical Inspection
598
Power off and on (System Unit) - All Models
598
Safety Labels
598
System Safety Inspection
598
Service Log
600
HSL Loop Configuration and Status Form
602
HSL Link Status Diagnosis Form
604
HSL Cable Location Form
605
Installed Features in a PCI Bridge Set Form
605
Terminology
606
Related Information for Analyze Hardware Problems
612
Version 5 Release
612
Notices
615
Trademarks
617
Advertisement
IBM iSeries 870 Hardware Problem Analysis And Isolation (512 pages)
Brand:
IBM
| Category:
Server
| Size: 7.35 MB
Table of Contents
Table of Contents
5
Analyze Hardware Problems
13
Start Problem Analysis
14
Starting Point for All Problems
14
Use the Service Action Log
19
Use the Product Activity Log
21
Use the Problem Log
21
Handle Problems for Non-Critical Resources
23
Analyze Intermittent Problems
23
Correct Intermittent Problems
24
Use this Intermittent Problem Section
24
General Intermittent Problem Checklist
25
How to Analyze the Intermittent Problem
28
Intermittent Symptoms
28
Failing Area INT-Pips
29
Analyze IPL Problems
30
Cannot Perform IPL at a Specified Time (no SRC)
31
Cannot Perform IPL from the Control Panel (no SRC)
31
Cannot Perform IPL from a Remote Location (no SRC)
35
System Hangs or Loops (no SRC)
38
Logical Partition Hangs or Loops (no SRC)
40
Cannot Automatically Perform an IPL after a Power Failure
42
Analyze Power Problems
43
Cannot Power on System Unit (no SRC)
43
System or Secondary Frame Cannot be Powered off
53
Cannot Power on Secondary Frame or Unit (no SRC)
55
Problem Isolation
73
Problem Isolation Procedures (Pips)
73
Bus, High-Speed Link (HSL) Pips
74
Breaking down the SRC
75
DSA Breakdown
75
Card Positions
77
Converting from HSL Loop Number to Port Labels on the System Unit or Processor Tower
84
Bus-PIP1
87
Bus-PIP2
87
Bus-PIP3
87
Bus-PIP5
87
Bus-PIP6
88
Bus-PIP7
88
Bus-PIP8
88
Bus PIP CNSL01
89
Bus-PIP10
89
Bus-PIP11
89
Bus-PIP9
89
Bus PIP HSL-01
91
Bus PIP HSL-02
94
Bus PIP HSL-03
96
Bus PIP HSL-04
97
Bus PIP HSL-05
99
Bus PIP HSL-06
99
Bus PIP HSL-07
100
Bus PIP HSL-08
100
Bus PIP IOP-01, IOP Reset
101
Bus PIP IOP-02, Isolate to Failing I/O Adapter Resource
102
Bus PIP IOP-03
104
Bus PIP MAB-02
106
Bus PIP MAB-03
107
Bus PIP MAB-04
109
Bus PIP PCIBUS-PIP1
111
Bus PIP Verify - RA
113
Communications PIP
115
Comm-Pip1
115
Disk Unit PIP
117
Du-Pip3
117
Intermittent Pips
120
INT-PIP3 External Noise on Ac Voltage Lines
120
INT-PIP5 External Noise on Twinaxial Cables
121
INT-PIP7 Electromagnetic Interference (EMI)
122
INT-PIP8 Grounding
122
INT-PIP9 Utility Power and Battery Power Units
124
INT-PIP14 Station Protectors
126
INT-PIP16 Licensed Internal Code
126
INT-PIP18 Ptfs Not Installed
126
INT-PIP20 Performance Problems
127
INT-PIP24 Service Processor Data Collection
127
Licensed Internal Code (LIC) Pips
128
Lic-Pip1
129
Lic-Pip3
130
Lic-Pip4
131
Lic-Pip7
132
Lic-Pip11
135
Lic-Pip8
135
Lic-Pip12
146
Lic-Pip13
150
Logical Partition (LPAR) PIP
156
Lpar-Pip01
156
Operations Console Pips
158
Operations Console-PIP1
159
Operations Console-PIP2
161
Operations Console-PIP3
162
Power Pips
164
Power PIP3
165
Power PIP4
165
Power PIP5
170
Power PIP6
172
Power PIP7
178
Power PIP8
180
Power PIP9
184
Power PIP11
187
Storage Device I/O Processor (SDIOP) Pips
197
Sdiop-Pip1
199
Sdiop-Pip13
201
Sdiop-Pip16
204
Sdiop-Pip17
207
Sdiop-Pip18
209
Sdiop-Pip19
211
Sdiop-Pip20
211
Sdiop-Pip21
213
Sdiop-Pip22
214
Sdiop-Pip23
214
Sdiop-Pip25
214
Sdiop-Pip26
216
Sdiop-Pip27
218
Sdiop-Pip28
219
Sdiop-Pip29
220
Sdiop-Pip30
220
Sdiop-Pip31
221
Sdiop-Pip32
222
Sdiop-Pip33
222
Sdiop-Pip34
223
Sdiop-Pip40
223
Sdiop-Pip41
224
Storage Device I/O Card FRU Locations
224
Service Processor Pips
225
Sp-Pip42
226
Sp-Pip43
226
Sp-Pip44
232
Sp-Pip45
232
System Power Control Network (SPCN) Pips
233
Spcn Pip1
234
Spcn Pip10
234
Spcn Pip20
234
Spcn Pip21
235
Tape Unit Pips
236
Tu-Pip1
236
Tu-Pip2
238
Tu-Pip3
240
Tu-Pip4
242
Tu-Pip6
246
Tape Unit Self-Test Procedure
247
Tape Device Ready Conditions
249
Twinaxial Workstation I/O Processor PIP
250
Twsc-Pip1
251
Workstation Adapter PIP
256
Ws-Pip1
257
Workstation Adapter Console PIP
259
Wsac-Pip1
260
Failing Items
261
Symbolic Frus
280
Acmodul
280
Airmovr
283
Ajdgp01
286
Altintf
286
Altmanl
289
Anybrdg
290
Anybus
290
Anyfc
290
Anymem
290
Anymemx
293
Anyproc
294
As4Ntdd
295
Auxcbl
296
Auxioa
296
Backpln
296
Batchgr
297
Batry
297
Bkspcn
298
Bpcpwr
299
Bpdpwr
299
Bpfpwr
300
Bprpwr
300
Bstwrpl
301
Bus1
301
BUSCBL1, BUSCBL2, BUSCBL3, or Buscblx
304
Buspwr
307
Busvpd
309
Cachbat
309
Cache
309
Cappwr
310
Cblall
310
Cblpwr
313
Ccin
315
Locations for Processors and Memory Frus
316
Processor Configuration
317
Cdawkld
330
Cdtray
330
Cecpwr
330
Check
331
Clkcard
332
Clckcrd
332
Cmpres1
333
Crypbat
333
Ctlpncd
334
Ctlpnl
335
Cvtcard
336
Dcapwr
336
Devbpln
337
Device
337
Devterm
337
DIMM 0
338
Dimm0_1
339
DIMM 1
339
DIMM 2
340
Dimm2_3
341
DIMM 3
342
Diskdrv
343
Diskimg
343
Disktry
344
Dmreg
344
Dpac
347
Drvswch
347
Dskdrv
347
Dsktry
347
Dskunit
348
Eacode
348
Extremd
348
Extscsi
348
Fccable
350
Fccode
350
Fcdev
350
Fcgate
350
Fcintf
351
Fcioa
351
Fcport
351
Hslctlr
352
Idpart
353
Intrlck
361
Ioacnfg
361
Iop
362
Iopwr
362
Iplintf
362
I2Cbus
365
Jtport
369
Lbsadp1
370
Lbsadp2
371
Lbsadp3
371
Lbsadp4
371
Lbsadp5
371
Lbusadp
371
Loc_Sys
372
Lparcfg
372
Lparsup
372
Lsmedia
372
Mabrcfg
373
Ma_Brdg
375
Mappwr
376
MAPPWR-1: the UEPO Switch on the Bulk Power Controller (BPC) Is in the Bypass Position
379
MAPPWR-2: There Is a Bulk Power Regulator (BPR) Communications Fault
379
MAPPWR-3: an Open Room EPO Switch Has Been Detected from One Side
380
MAPPWR-4: There Is a 350 V Bulk Failure
381
MAPPWR-5: an Air Flow Loss Has Been Detected
382
MAPPWR-6: There Is a Processor (Critical/Warning) Overtemperature Fault
383
MAPPWR-7: There Is a Bulk Power Assembly (BPA) Communication Failure
384
MAPPWR-8: Loss of Ac Power or Phase Missing
385
MAPPWR-9: 2.5 V Current/Voltage Problem in Processor Subsystem
387
MAPPWR-A: 1.8 V Current/Voltage Problem in Processor Subsystem
390
MAPPWR-B: 1.5 V Auxiliary Current/Voltage Problem in Processor Subsystem
394
MAPPWR-C: 1.5 V CPU Current/Voltage Problem in Processor Subsystem
398
MAPPWR-D: 3.3 V Current/Voltage Problem in Processor Subsystem
400
MAPPWR-E: 5.0 V Current/Voltage Problem in Processor Subsystem
404
MAPPWR-F: Cable Problem in Power Subsystem
407
MAPPWR-G: a UEPO Panel Fault Has Been Detected
410
MAPPWR-H: an MCM Fault Has Been Detected
410
MAPPWR-J: There Is a Bulk Power Enclosure (BPE) Communication Failure
411
Masbus
411
Mdapwr
412
Media
413
Memcfg
413
Memory
413
Memory for 2890 Integrated Xseries Server (IXS) Card
414
Memory for 2892 Integrated Xseries Server (IXS) Card
415
Message
415
Moveioa
415
Msapwr
415
Mstore
416
Mumiocd
417
Netserv
418
Nextlvl
418
Nofrus
418
Nomsuse
418
Nscable
418
Ntdevdr
418
Ntlandd
418
Ntopsys
418
Ntuser
418
Ntvscsi
419
Opt_Cln
419
Optlcbl
419
Optldrv
419
Opuser
419
Pcibus
419
Pgdpart
419
Piocard
427
Plus
428
Ppcimin
429
Ppcisys
429
Ppcitwr
430
Pri_Pci
430
Primioa
431
Proc
431
Procmm
431
Procode
432
Proc0
432
Proc1
432
Proc2
432
Proc3
432
Ptfsrch
432
Pwroc
433
Pwrreg
437
Pwrsply
443
Qsysopr
455
Redh
455
Refer
456
Rem_Nic
456
Rem_Sys
456
Rioport
456
Rmdev
458
Siadpcd
458
Si_Card
459
Sicntrl
460
Siioadp
462
Si_Phb
464
Sirgcbl
465
Sirgcfg
468
Sirstat
469
Sloterr
474
Snsdata
475
Spcncrd
475
Spnlcrd
475
Storioa
475
Svcdocs
476
Svcproc
476
Sysbkpl
476
Sysbkex
478
Sysunit
479
Tapcln
481
Tapcnfg
481
Tod
481
Twrbkpl
481
Twrcard
482
Twrplnr
485
Uc235
486
Uc236
486
Ug3As
486
Uj0E7
486
Uj6P3
486
Uja34
487
Uje34
487
Uje35
487
Uje40
487
Ulnz3
488
Ulnz4
488
Unp20
488
Uplf1
488
Upsunit
488
User
489
Ux201
489
Ux202
489
Uy1Z1
490
Uy1Z2
490
Uy1Z3
490
Uy1Z4
490
Uy1Z5
490
Vpdconc
491
Vpdpart
491
Notices
505
Trademarks
507
Version 5 Release
509
IBM iSeries 870 Analyze Hardware Problems (System Reference Codes (306 pages)
Brand:
IBM
| Category:
Server
| Size: 1.62 MB
Table of Contents
Laser Safety Information
9
Product Recycling and Disposal
9
Battery Return Program
9
Environmental Design
9
Advertisement
Advertisement
Related Products
IBM 87302RU
IBM 87401RU
IBM 87691VX VXA320
IBM 8654 - Eserver xSeries 330
IBM 86494AX
IBM 86495AX
IBM 86857RX
IBM 88622RX
IBM 88728RU
IBM 8840 - eServer xSeries 346
IBM Categories
Server
Desktop
Storage
Laptop
Monitor
More IBM Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL