The cooking zones are equipped with a Booster or
TwinBooster (see "Guide to the appliance").
When activated, the power is boosted for a maximum of
15 minutes so that large quantities can be heated up quickly,
e.g. when boiling water for cooking pasta.
The Booster function can only be used on two cooking zones
at the same time.
If the Booster function is switched on when
– no setting has been selected, the cooking zone will revert
automatically to setting 9 at the end of the booster time or if
the booster function is switched off before this.
– a setting has been selected, the cooking zone will revert
automatically to the setting selected at the end of the
booster time or if the booster function is switched off
before this.
Taking a pan off the zone whilst the Booster is in operation
will not interrupt the Booster time.
Cooking zones are networked in pairs to supply the power for
the Booster function.
When the Booster function is selected, a proportion of energy
is taken away from the linked cooking zone and the following
happens within the pairs:
- Auto heat-up is deactivated
- The power level is reduced
- The linked cooking zone is switched off.
In TwinBooster level II, the entire available power is
concentrated on the selected cooking zone, while Booster
B II or TwinBooster BI allows another cooking zone on the
same circuit to be in operation.