hit counter script

Siemens RF182C Operating Instructions Manual page 115

Rfid systems
Table of Contents

Advertisement

GetReaderStatus mode = 06
Byte
0
1
Param
S-Info
FZP
Parameter name
S-Info
FZP
ABZ
CFZ
SFZ
CRCFZ
BSTAT
ASMFZ
res.
RF182C communication module
Operating Instructions, 10/2010
2
3
4
5
ABZ
CFZ
SFZ CRCFZ
Command and acknowledgement telegrams
6
7
8 ... 26
BSTAT
ASMFZ
res.
Comment
Reader status mode information = 06
Error counter, passive (errors during idle time)
Abort counter
Code error counter
Signature error counter
CRC error counter
Current command status
Interface error counter for ASM
Spare