Communication interface
6.4 Commands of the communication module
6.4.4
getReaderStatus
The command requests diagnostic/status information from the connected reader.
Below the XML command for the reader status (getReaderStatus) is described:
XML command
<command>
</command>
XML response
Below the XML response without error entry (for error entries, see section Error messages
(Page 71)) is described:
<reply>
</reply>
Parameter
Parameter
Mode
Data
Reader status acknowledgement message frame
An acknowledgment message frame on the reader status is returned via the "Data"
parameter. Different acknowledgment message frames are returned depending on the set
"mode". All available acknowledgment message frames can be found in section Command
and acknowledgement telegrams (Page 111).
56
<getReaderStatus>
<mode>Mode</mode>
</getReaderStatus>
<resultCode>Errorcode</resultCode>
<getReaderStatus>
<returnValue>
<data>Data</data>
</returnValue>
</getReaderStatus>
Data type
ASCII hex
ASCII hex
Values
00 ... FF (2 x ASCII)
01 = reader status
02 = MOBY U (SLG diagnostics I, function calls)
03 = MOBY U (SLG diagnostics II, error messages)
04 = MOBY U (SLG diagnostics III, identified MDS)
05 = MOBY U (SLG diagnostics IV, communication
performance)
06 = RF300 reader diagnostics
07 = RF600 reader diagnostics
0000 ... FFFF (ASCII string (max. 400 x ASCII))
An acknowledgment message frame on the reader status is
returned.
RF182C communication module
Operating Instructions, 10/2010