Nokia Customer Care
Baseband tuning
Energy management calibration
Before you begin
External power is needed.
Energy management calibration is used for calibrating the battery and charger settings of the phone.
Preparation for energy management calibration:
• Charger calibration: Connect DC cable CA-5S between JBV-1 and VIN of the phone.
• Connect 12...15 V from the external power supply to JBV-1.
Note:
Make sure that FBUS connection is used. This calibration does not work with MBUS.
Steps
Tuning > Energy Management Calibration .
1. Select
Check the values to calibrate.
Select "Read from phone" to show the current values in the phone memory, and then check that the
communication with the phone works.
2. Select "Calibrate" to run selected calibrations..
Page 7 –34
Figure 100 Select energy management calibration
COMPANY CONFIDENTIAL
Copyright © 2005 Nokia. All rights reserved.
Baseband troubleshooting for analysis
RM-82
Issue 1