Error Code Description
406F 0BFB Error code generation/logging detected fault in
I/O hub chip 11 (port x)
406F 0BFC Error code generation/logging detected fault in
I/O hub chip 12 (port x)
406F 0BFD Error code generation/logging detected fault in
I/O hub chip 13 (port x)
406F 0C03 Error code generation/logging detected fault in
all MCMs
406F 0C09 Error code generation/logging detected fault in
all memory books
406F 0C0A Error code generation/logging detected fault in
all I/O books
406F 0C10 Error code generation/logging detected
mismatch between MCM 0 and VPD card
406F 0C11 Error code generation/logging detected
mismatch between MCM 2 and VPD card
406F 0C12 Error code generation/logging detected
mismatch between MCM 1 and VPD card
406F 0C13 Error code generation/logging detected
mismatch between MCM 3 and VPD card
406F 0CA5 Error code generation/logging detected invalid
processor subsystem configuration
406F 0CA6 Error code generation/logging detected no
usable main storage
406F 0CA9 Error code generation/logging detected
configuration error with processor memory
406F 0D00 Error code generation/logging detected fault in
L3 cache module 0
406F 0D01 Error code generation/logging detected fault in
L3 cache module 1
406F 0D02 Error code generation/logging detected fault in
L3 cache module 2
406F 0D03 Error code generation/logging detected fault in
L3 cache module 3
Action/
Possible Failing FRU
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H3/Q1
b. U1.18-P1-H3/Q2
2. Replace the RIO book,
Location: U1.18-P1-H3
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H4/Q1
b. U1.18-P1-H4/Q2
2. Replace the RIO book,
Location: U1.18-P1-H4.
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H4/Q3
b. U1.18-P1-H4/Q4
2. Replace the RIO book,
Location: U1.18-P1-H4
Go to "MAP 1543: MCM Module Problem
Isolation" on page 339.
Go to "MAP 1546: Memory Book Problem
Isolation" on page 347.
Go to "MAP 1547: I/O Book Problem Isolation"
on page 350.
Plugging error with FRU kit
Location: U1.18-P1-C1 and U1.18-P1-H2.3
Plugging error with FRU kit
Location: U1.18-P1-C4 and U1.18-P1-H2.4
Plugging error with FRU kit
Location: U1.18-P1-C3 and U1.18-P1-H2.5
Plugging error with FRU kit
Location: U1.18-P1-C2 and U1.18-P1-H2.6
Verify that MCMs, memory books, and L3
modules are correctly configured.
Reboot the system in slow mode to isolate the
failure.
Reboot the system in slow mode to isolate the
failure.
L3 cache module 0 and L3 VPD card
Location: U1.18-P1-C6 and U1.18-P1-H2.1
L3 cache module 1 and L3 VPD card
Location: U1.18-P1-C7 and U1.18-P1-H2.1
L3 cache module 2 and L3 VPD card
Location: U1.18-P1-C11 and U1.18-P1-H2.1
L3 cache module 3 and L3 VPD card
Location: U1.18-P1-C10 and U1.18-P1-H2.1
Chapter 5. Error Code to FRU Index
673