56 | Viewing information
Menu structure INFO
Thermal disinfection
PE: Therm disinfect
pump status
Solar optimization
Solar yield last hour
Solar yield today
Solar yield overall
DHW temperature
reduced by
Desired room temp HC 1
reduced by
Desired room temp HC 2
reduced by
Faults
6 720 643 256 (2010/05)
Display (example)
–
Running | Off
–
409 BTU (120 Wh)
8.12 MBTU (2.38 kWh)
1649.1 MBTU (483.6 kWh) Total solar energy yield since commissioning.
8.4 °F (4.7 °C)
2.4 °F (1.3 °C)
2.4 °F (1.3 °C)
40 Solar system
03 FW 200
EA Boiler
...
Description
Menu for thermal disinfection part of the system.
Status of thermal disinfection pump (PE).
Menu for solar-assisted optimization of conventional
heating system.
Solar energy yield in the last hour (a figure is only
shown if correct parameters have been set on the
Solar optimization menu,
page 80).
Solar energy yield for the current 24 hour period.
Current reduction of the specified domestic hot
water temperature required by the boiler as a result
of the available solar energy. Does not start until at
least 30 days after commissioning.
Current reduction of desired room temperature for
heating circuit based on available solar energy. Does
not start until at least 30 days after commissioning.
Current reduction of desired room temperature for
heating circuit 2 based on available solar energy.
Does not start until at least 30 days after
commissioning.
List of current faults. More detailed information can
be obtained by selecting with the dial
pressing the dial
US/CA
Section 8.5.10 on
and then
to confirm.