6. GENERAL GAIN ADJUSTMENT
6.2.2 Auto tuning mode operation
The block diagram of real-time auto tuning is shown below.
Command
DRU parameter
No.8
Auto tuning selection
When a servo motor is accelerated/decelerated, the load inertia moment ratio estimation section always
estimates the load inertia moment ratio from the current and speed of the servo motor. The results of
estimation are written to DRU parameter No. 12 (the ratio of load inertia moment to servo motor). These
results can be confirmed on the status display screen of the MR Configurator (servo configuration
software section).
If the value of the load inertia moment ratio is already known or if estimation cannot be made properly,
chose the "auto tuning mode 2" (DRU parameter No.8:0003) to stop the estimation of the load inertia
moment ratio (Switch in above diagram turned off), and set the load inertia moment ratio (DRU
parameter No. 12) manually.
From the preset load inertia moment ratio (DRU parameter No. 12) value and response level (DRU
parameter No. 9), the optimum control gains are automatically set on the basis of the internal gain tale.
The auto tuning results are saved in the servo system controller every 10 minutes since power-on. At
power-on, auto tuning is performed with the value of each control gain saved in the servo system
controller being used as an initial value.
Automatic setting
Control gains
PG1,VG1
PG2,VG2,VIC
Set 0 or 1 to turn on.
Gain
table
DRU parameter
No.9
Response level setting
POINT
If sudden disturbance torque is imposed during operation, the estimation
of the inertia moment ratio may malfunction temporarily. In such a case,
choose the "auto tuning mode 2" (DRU parameter No. 8: 0003) and set the
correct load inertia moment ratio in DRU parameter No. 12.
When any of the auto tuning mode 1, auto tuning mode 2 and manual
mode 1 settings is changed to the manual mode 2 setting, the current
control gains and load inertia moment ratio estimation value are saved in
the EEP-ROM.
www.dadehpardazan.ir 88594014-15
Current feedback
Real-time auto
tuning section
Load inertia
moment ratio
Switch
estimation section
DRU parameter No.12
Load inertia moment
ratio estimation value
6 - 5
Load inertia
moment
Current
Servo
control
motor
Position/speed
feedback
Speed feedback
Encoder