hit counter script

Siemens SIMOTICS M-1PH818 Operating And Installation Instructions page 253

Main motors
Table of Contents

Advertisement

K3G250-RR03-M4
Siemens AG PD LD Nbg.
2. INTENDED USE
The device is exclusively designed as a built-in device for conveying
air according to its technical data.
Any other usage above and beyond this does not conform with the
intended purpose and constitutes misuse of the device.
Customer equipment must be capable of withstanding the mechanical
and thermal stresses that can arise from this product. This applies for the
entire service life of the equipment in which this product is installed.
Intended use also includes
Using the device only in power systems with grounded neutral (TN/
TT power systems) and in ungrounded IT power systems.
The device is to be used in networks with network quality
characteristics as per EN 50160.
Use of the device in stationary systems only.
Conveying air at an ambient air pressure between 800 mbar and
1050 mbar.
Using the device within the permitted ambient temperature range; see
Chapter 3.6 Transport and storage conditions and
Chapter 3.2 Nominal data.
Operating the device with all protective devices.
Following the operating instructions.
Improper use
In particular, operating the device in the following ways is prohibited and
could be hazardous:
Operating the device in an unbalanced state, e.g. due to dirt deposits
or ice formation.
Resonant operation, operation with severe vibration. This also
includes vibration transmitted to the fan from the customer installation.
Opening the terminal box during operation.
Conveying air that contains abrasive particles.
Conveying highly corrosive air, e.g. salt spray. Exception: devices
designed for salt spray and correspondingly protected.
Conveying air with high dust content, e.g. suctioning off sawdust.
Operating the device close to flammable materials or components.
Operating the device in an explosive atmosphere.
Using the device as a safety component or to perform safety-related
functions.
Operation with completely or partially disassembled or manipulated
protective devices.
In addition, all applications not listed among the intended uses.
Item no. 55691-5-9970 · ENU · Change 94618 · Approved 2017-06-12 · Page 3 / 12