Examples
To be able to transfer a data record to the positioning module, you must supply the following par-
ameters to the function block:
Mode (BA), source (Q-DB, QANF) and destination parameter (Z-DB)
Parameters not required are assigned KF+O.
Example:
Parameter assignment to transfer machine data (PC-A P247):
- Mode BA:
- Source DB Q-DB :
- Source start QANF :
- Dest. DB Z-DB:
- Dest. start ZANF :
The machine data DB (DB1 04) in the PC memory is transferred as machine data DB (DB1 O) to
the IP247 memory.
If the machine data record is to be deleted, the following parameter assignment must be made:
- Mode BA:
- Source DB Q-DB:
- Source start QANF:
- Dest. DB Z-DB:
- Dest, start ZANF:
The machine data DB (DB1 O) on the positioning module is deleted.
6 - 6 8
= DB104 PC memory
= DWO from DWO
= irrelevant
= DB1O IP247 memory
=
irrelevant