Page 1
AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED LG Electronics India Pvt. Ltd. Regd. Office: A-27, Mohan Cooperative Industrial MFL39754850 Estate, Mathura Road, New Delhi-1 10044. www.lg.com...
Page 2
(Recommended 24°C is suitable for human body) (Refer page no. 20 and 21 for details)
Page 6
1. When this crossed-out wheeled bin symbol is attached to a product it means the product is covered by the e-waste (Management and Handling) Rules, 2011. 2. All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities.
ADVANCED FUNCTIONS Changing room temperature quickly Air purification mode Indoor air purification – Auto Clean operation – Plasma Purification operation Auto operation Quiet Mode (optional) Energy Saver mode – Prior to operation Dimmer – Components Operating the air conditioner without the –...
Prior to Operation Preparing for Operation Cleaning and Maintenance 1. Contact an installation specialist for 1. Do not touch the metal parts of the unit installation. when removing the filter. Injury can occur. 2. Plug in the power plug properly. 2.
Page 9
Components Symbols used in this Manual This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that may cause harm to the air conditioner. Notice This symbol indicates special notes. Features WARNING This appliance should be installed in accordance with national wiring regulations. This guide acts as a guide to help to explain product features.
Electrical Safety WARNING • This appliance must be properly grounded. To minimize the risk of electric shock, you must always plug into a grounded outlet. • Do not cut or remove the grounding. • Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.
Using the remote control You can operate the air conditioner more conveniently with the remote control. You will find the buttons for the additional functions under the cover of the remote control. Wireless remote control Control panel Display Screen Description ON/OFF BUTTON POWER Turns the power on/off.
BASIC FUNCTIONS Cooling your room POWER MODE Following is the display on the display screen. POWER MODE (Heating operation / Heat Pump model only) POWER MODE Following is the display on the display In this mode indoor unit fan and outdoor screen.
Page 14
Selectable Air Swing (Horizontal) (Optional) To adjust the direction of the air flow hori- zontally. POWER Open the remote control cover while the air conditioner is in operation. to select the air circulatiion Press the 2ndF Button. operation. Press the HORIZONTAL VANE CONTROL BUTTON.
Page 15
Check if icon is off. Press 2 F button and check if icon is on. Press the TIMER SET/CANCEL BUTTON aiming the remote controller at the signal Press to set the desired ON time. receiver. ON–TIMER – The icon below is displayed on the (The timer lamp on the air conditioner and display screen.
Page 16
ADVANCED FUNCTIONS Air Purification Mode (Optional) LG Air conditioner come with a variety of filters like Anti-Bacteria filter, Tripple Filter, Virus & Allergy safe filter, Plasma Filter, which enable you to use it as a Built-in Air purifier (Even when you are not using it for cooling, hence minimal electricity consumption).
ADVANCED FUNCTIONS Plasma Purification operation (Optional) Press POWER to turn on the power. Press POWER to turn on the power. AUTO CLEAN Both the plasma lamp and the power lamp light up whi le plasma purification is in operation. During Auto Clean function, “Co” will be displayed on the unit.
ADVANCED FUNCTIONS Auto changeover operation this operation is basically heating or cooling function of the air conditioner. But during this operation the controller change the operation mode automatically to keep the temperature within ° ±2 C with respect to the setting temperature. Press POWE R to turn on the power.
ADVANCED FUNCTIONS Quiet Mode Operation Following is displayed on the display screen. (Optional) This mode minimizes the fan speed of the system hence making the environment more comfortable and silent. Press POWER to turn on the power. 2. Open the remote control cover. QUIET 3.
Page 20
ADVANCED FUNCTIONS restart (Optional) Heat pump Model Cooling Model Room Temp. 24°C 21°C Room Temp. < 24°C Room Temp. < 21°C Operating mode Cooling Cooling Healthy Dehumidification Heating Indoor FAN Speed High High High High Setting Temperature 22°C 22°C 23°C 24°C...
MAINTENANCE Caution Plz do not press the mesh with finger as shown above Outdoor Unit (Rear) The heat exchanger coils and panel vents of the outdoor unit should (Side) Air intake be checked regularly. If clogged with dirt or soot, the heat exchanger Piping vents and panel vents may be professionally steam cleaned.
TROUBLESHOOTING When the air conditioner is not going to be used for a long time. When air conditioner is not going to be When the air conditioner is to be used again. used for a long time. Clean the air filter and install it in the indoor Operate the air conditioner on Air circulation mode (Refer to page 23) for 2 to 3 hours.