Siemens SITOP 6EP1336-3BA00 Manual

Siemens SITOP 6EP1336-3BA00 Manual

Power supply, modular 1ph/2ph

Advertisement

SITOP power supply
SITOP modular 1ph/2ph
Manual
SITOP PSU200M 24 V/5 A
6EP1333-3BA10
SITOP PSU200M 24 V/10 A
6EP1334-3BA10
SITOP modular 24 V/20 A
6EP1336-3BA00
SITOP PSU100M 24 V/40 A
6EP1337-3BA00
04.2018
C98130-A7548-A1-4-7629
___________________
Overview
___________________
Safety instructions
___________________
Description, device design,
dimension drawing
___________________
Mounting/removal
___________________
Mounting position, mounting
clearances
___________________
Installation
___________________
Technical data
___________________
Safety, approvals, EMC
___________________
Ambient conditions
___________________
Applications
___________________
Environment
___________________
Service & Support
1
2
3
4
5
6
7
8
9
10
11

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SITOP 6EP1336-3BA00

  • Page 1 ___________________ Overview ___________________ Safety instructions ___________________ Description, device design, SITOP power supply dimension drawing ___________________ Mounting/removal SITOP modular 1ph/2ph ___________________ Mounting position, mounting clearances ___________________ Installation Manual ___________________ Technical data ___________________ Safety, approvals, EMC ___________________ Ambient conditions ___________________ Applications ___________________ Environment ___________________ Service &...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Overview

    Overview The 1-phase/2-phase power supply from the SITOP modular product line is a powerful, stabilized technology power supply for automated machines and systems. The key benefits of the product include: ● Wide-range input, which allows it to be connected to almost any 1-phase/2-phase line supply around the world ●...
  • Page 4 Overview Ordering data The following device options are available: Stabilized power supply unit SITOP modular 1ph/2ph Type Order number 120-230/230-500 VAC input, 6EP1333-3BA10 24 V/5 A output 120-230/230-500 VAC input, 6EP1334-3BA10 24 V/10 A output 120/230 VAC input, 6EP1336-3BA00 24 V/20 A output 120/230 VAC input, 6EP1337-3BA00 24 V /40 A output...
  • Page 5: Table Of Contents

    Table of contents Overview..............................3 Safety instructions ........................... 7 General safety instructions ....................... 7 Safety instructions for hazardous zones ................... 7 Description, device design, dimension drawing..................9 Device description ........................9 Connections and terminal designation..................10 Potentiometer .......................... 12 Status displays and signaling ....................13 Change-over switch ........................
  • Page 6 Table of contents Dimension drawing ........................ 50 Safety, approvals, EMC ........................51 Safety ............................. 51 Test voltage ..........................52 Approvals ..........................53 EMC ............................54 Ambient conditions ..........................55 Applications ............................57 Parallel connection to increase power rating ................. 57 Parallel connection for redundancy ..................
  • Page 7: Safety Instructions

    Safety instructions General safety instructions WARNING Correct handling of the devices When operating electrical devices, it is inevitable that certain components will carry dangerous voltages. Therefore, failure to handle the units properly can result in death or serious physical injury as well as extensive property damage.
  • Page 8 Safety instructions 1.2 Safety instructions for hazardous zones SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 9: Description, Device Design, Dimension Drawing

    Description, device design, dimension drawing Device description SITOP modular is a primary-clocked power supply for connection to a 1-phase/2-phase AC line supply. An electronically regulated DC voltage that can be set via a potentiometer is available at the output of the device. The output of the device is isolated, no-load proof and short-circuit proof.
  • Page 10: Connections And Terminal Designation

    Description, device design, dimension drawing 2.2 Connections and terminal designation Connections and terminal designation ① The line input terminals can be used to establish the connection to the supply voltage. ② The output terminals are used to connect to the loads to be supplied (see also Section Installation (Page 33)).
  • Page 11 Description, device design, dimension drawing 2.2 Connections and terminal designation Connections and terminal designations for 6EP1336-3BA00 and 6EP1337-3BA00 ① One screw terminal each Line input L1, N (L2), PE, Jump 120 V AC ② 2 screw terminals Output + ② 2 screw terminals Output –...
  • Page 12: Potentiometer

    Description, device design, dimension drawing 2.3 Potentiometer Potentiometer ③ The potentiometer on the front of the device is used to set the output voltage. The output voltage is set to 24 V in the factory, and can be adjusted in the range 24 - 28.8 V; for example, to compensate voltage drops across long supply lines to the connected load.
  • Page 13: Status Displays And Signaling

    Description, device design, dimension drawing 2.4 Status displays and signaling Status displays and signaling 6EP1333-3BA10 (24 V/5 A) 6EP1336-3BA00 (24 V/20 A) 6EP1337-3BA00 (24 V/40 A) 6EP1334-3BA10 (24 V/10 A) Status indicator Green LED for 24 V O.K. Yellow LED for overload in "constant current" mode Red LED for latching shutdown in "shut down"...
  • Page 14: Change-Over Switch

    Description, device design, dimension drawing 2.5 Change-over switch Change-over switch Figure 2-7 A/B selector switch The two switches A and B are used to influence the output characteristic: Switch Parallel operation: Single operation: Delivery state influences the output 'Soft' characteristic curve (see, e.g. Figure 6-10 characteristic in the 6EP1333-3BA10 parallel operation output char- load range...
  • Page 15 Description, device design, dimension drawing 2.5 Change-over switch Selector switch for the input voltage range for 6EP1333-3BA10 (24 V/5 A) and 6EP1334- 3BA10 (24 V/10 A) Figure 2-8 Voltage selector switch (example, 6EP1334-3BA10) The selector switch as delivered is in the 230 V position. It must be moved to the appropriate position for operation in the 120 V range.
  • Page 16: Block Diagram

    Description, device design, dimension drawing 2.6 Block diagram Block diagram Figure 2-10 Block diagram for 6EP1333-3BA10 and 6EP1334-3BA10 SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 17 Description, device design, dimension drawing 2.6 Block diagram Figure 2-11 Block diagram for 6EP1336-3BA00 and 6EP1337-3BA00 SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 18: Dimensions And Weight

    Description, device design, dimension drawing 2.7 Dimensions and weight Dimensions and weight Figure 2-12 Dimension drawing, 6EP1333-3BA10 and 6EP1334-3BA10 (example, 6EP1334-3BA10) Figure 2-13 Dimension drawing for 6EP1336-3BA00 SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 19 Description, device design, dimension drawing 2.7 Dimensions and weight Figure 2-14 Dimension drawing for 6EP1337-3BA00 6EP1333-3BA10 6EP1334-3BA10 6EP1336-3BA00 6EP1337-3BA00 (24 V/5 A) (24 V/10 A) (24 V/20 A) (24 V/40 A) Dimensions 70 × 125 × 120,5 70 × 125 × 120,5 160 ×...
  • Page 20 Description, device design, dimension drawing 2.7 Dimensions and weight SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 21: Mounting/Removal

    Mounting/removal WARNING Installing the device in a housing or a control cabinet The SITOP modular power supply is a built-in device. It must be installed in a housing or control cabinet, to which only qualified personnel have access. The device can be mounted in a control cabinet on standard mounting rails (see Chapter Mechanical system (Page 49)) Mounting To mount the device, position it with the mounting rail guide at the upper edge of the...
  • Page 22 Mounting/removal WARNING Use in hazardous zones If the devices are installed in a hazardous zone (Ex II 3G Ex nA nC IIC T3 (T4) Gc or Ex II 3G Ex nA IIC T3 Gc), they must be installed in a distribution box with degree of protection IP54 or higher.
  • Page 23: Mounting Position, Mounting Clearances

    Mounting position, mounting clearances Standard mounting position The device is mounted on standard mounting rails according to EN 60715. The device must be mounted vertically in such a way that the input terminals and the output terminals are at the bottom to ensure correct cooling. A clearance of at least 50 mm should be maintained above and below the device (maximum depth of the cable duct, 50 mm).
  • Page 24 Mounting position, mounting clearances 4.1 Standard mounting position Figure 4-3 6EP1336-3BA00: Output current in the standard mounting position Figure 4-4 6EP1337-3BA00: Output current in the standard mounting position Figure 4-5 Mounting height derating For details, see Ambient conditions (Page 55) SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 25: Other Mounting Positions

    Mounting position, mounting clearances 4.2 Other mounting positions Other mounting positions For mounting positions that deviate from the standard mounting position, derating factors (reduction of the output power or the permissible ambient temperature) must be observed in accordance with the following diagrams. Note In the case of mounting positions that deviate from the standard mounting position, reduced mechanical resistance of the devices against vibration and shock must be expected.
  • Page 26 Mounting position, mounting clearances 4.2 Other mounting positions Figure 4-8 6EP1333-3BA10 mounting position (3) Figure 4-9 6EP1333-3BA10 mounting position (4) Figure 4-10 6EP1333-3BA10 mounting position (5) SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 27: 6Ep1334-3Ba10

    Mounting position, mounting clearances 4.2 Other mounting positions 4.2.2 6EP1334-3BA10 Figure 4-11 6EP1334-3BA10 mounting position (1) Figure 4-12 6EP1334-3BA10 mounting position (2) Figure 4-13 6EP1334-3BA10 mounting position (3) SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 28 Mounting position, mounting clearances 4.2 Other mounting positions Figure 4-14 6EP1334-3BA10 mounting position (4) Figure 4-15 6EP1334-3BA10 mounting position (5) SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 29: 6Ep1336-3Ba00

    Mounting position, mounting clearances 4.2 Other mounting positions 4.2.3 6EP1336-3BA00 Figure 4-16 6EP1336-3BA00 mounting position (1) Figure 4-17 6EP1336-3BA00 mounting position (2) Figure 4-18 6EP1336-3BA00 mounting position (3) SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 30 Mounting position, mounting clearances 4.2 Other mounting positions Figure 4-19 6EP1336-3BA00 mounting position (4) Figure 4-20 6EP1336-3BA00 mounting position (5) SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 31: 6Ep1337-3Ba00

    Mounting position, mounting clearances 4.2 Other mounting positions 4.2.4 6EP1337-3BA00 Figure 4-21 6EP1337-3BA00 mounting position (1) Figure 4-22 6EP1337-3BA00 mounting position (2) SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 32 Mounting position, mounting clearances 4.2 Other mounting positions Figure 4-23 6EP1337-3BA00 mounting position (3) Figure 4-24 6EP1337-3BA00 mounting position (4) Figure 4-25 6EP1337-3BA00 mounting position (5) SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 33: Installation

    Installation WARNING Hazard due to electric shock Before installation or maintenance work can begin, the system's main switch must be switched off and measures taken to prevent it being switched on again. If this instruction is not observed, touching live parts can result in death or serious injury. Line-side connection The SITOP modular power supply is designed for connection to a 1/2 phase AC line supply (TN, TT or IT system according to IEC 60364-1) with a rated voltage of 120-230/230-500 V...
  • Page 34 Installation 5.1 Line-side connection between line conductors L1 and L2 and an RCD is used as protection against direct or indirect contact, then only an AC/DC-sensitive RCD type B is permitted. Protection SITOP modular Line-side protection recommended for 1-phase operation or required for 2-phase operation 6EP1333-3BA10 1-phase operation: Miniature circuit breaker (IEC 898), characteristic C (B), 6 A (10 A) •...
  • Page 35: Output-Side Connection

    Installation 5.2 Output-side connection Output-side connection At its output, the SITOP modular power supply provides an isolated (= non-grounded) SELV output voltage (Safety Extra Low Voltage). The output of the power supply is no-load, overload, and short-circuit proof. If an overload occurs, the electronic current limiting function limits the output current to a maximum value (refer to Chapter Technical data (Page 37)).
  • Page 36 Installation 5.2 Output-side connection SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 37: Technical Data

    Technical data Note Technical data is applicable for a rated input voltage of 230 V AC, rated load and 25 °C ambient temperature (if nothing else is specified). Input 6EP1333-3BA10 6EP1334-3BA10 6EP1336-3BA00 6EP1337-3BA00 (24 V/5 A) (24 V/10 A) (24 V/20 A) (24 V/40 A) Input 1-phase and 2-phase AC...
  • Page 38 Technical data 6.1 Input 6EP1333-3BA10 6EP1334-3BA10 6EP1336-3BA00 6EP1337-3BA00 (24 V/5 A) (24 V/10 A) (24 V/20 A) (24 V/40 A) Integrated input fuse Fuse Fuse Fuse Fuse T 3.15 A T 6.3 A T 10 A T 16 A Protection in the line Recommended for 1-phase operation: Minia- Recommended for 1- Recommended for 1-...
  • Page 39: Output

    Technical data 6.2 Output Output 6EP1333-3BA10 6EP1334-3BA10 6EP1336-3BA00 6EP1337-3BA00 (24 V/5 A) (24 V/10 A) (24 V/20 A) (24 V/40 A) Output Regulated, isolated DC voltage Rated voltage U 24 V out rated Total tolerance, static ± Static line regulation, approx. 0.1 % 0.1 % 0.1 %...
  • Page 40 Technical data 6.2 Output 6EP1333-3BA10 6EP1334-3BA10 6EP1336-3BA00 6EP1337-3BA00 (24 V/5 A) (24 V/10 A) (24 V/20 A) (24 V/40 A) Short-time overload current for 15 A 30 A 60 A 120 A a short circuit in operation, typ. Duration of the overload capa- 25 ms 25 ms 25 ms...
  • Page 41 Technical data 6.2 Output Figure 6-3 6EP1333-3BA10 single operation output characteristic Figure 6-4 6EP1334-3BA10 single operation output characteristic Figure 6-5 6EP1336-3BA00 single operation output characteristic SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 42 Technical data 6.2 Output Figure 6-6 6EP1337-3BA00 single operation output characteristic The device supplies a constant output voltage until the current limit is reached. In the event of an overload, the output current and the output voltage are reduced. Derating for U >...
  • Page 43 Technical data 6.2 Output Derating for U > 24 V depending on the input voltage (only valid for 6EP1337-3BA00): Figure 6-9 Output derating depending on the input voltage For 85 to 93 V AC, it is not permissible that the output voltage is set higher than 24 V. Selector switch A closed: Parallel operation The output voltage falls with increasing output current.
  • Page 44 Technical data 6.2 Output Figure 6-12 6EP1336-3BA00 parallel operation output characteristic Figure 6-13 6EP1337-3BA00 parallel operation output characteristic Selector switch B closed: Latching shutdown. The device is shutdown if the overload lasts longer than 100 ms. Turning the power supply off for longer than 5 s causes a reset. Figure 6-14 6EP1333-3BA10 latching shutdown output characteristic SITOP modular 1ph/2ph...
  • Page 45 Technical data 6.2 Output Figure 6-15 6EP1334-3BA10 latching shutdown output characteristic Figure 6-16 6EP1336-3BA00 latching shutdown output characteristic Figure 6-17 6EP1337-3BA00 latching shutdown output characteristic SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 46: Efficiency

    Technical data 6.3 Efficiency Efficiency 6EP1333-3BA10 6EP1334-3BA10 6EP1336-3BA00 6EP1337-3BA00 (24 V/5 A) (24 V/10 A) (24 V/20 A) (24 V/40 A) Efficiency at U 88 % 91 % 89 % 88 % out rated , approx. out rated Power loss at U 17 W 24 W 59 W...
  • Page 47 Technical data 6.3 Efficiency Figure 6-20 6EP1336-3BA00 efficiency Figure 6-21 6EP1337-3BA00 efficiency SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 48: Closed-Loop Control

    Technical data 6.4 Closed-loop control Closed-loop control 6EP1333-3BA10 6EP1334-3BA10 6EP1336-3BA00 6EP1337-3BA00 (24 V/5 A) (24 V/10 A) (24 V/20 A) (24 V/40 A) Dyn. line regulation 0.1 % 0.1 % ±15 %), max. in rated Dyn. load regulation : 50/100/50 %), U ±...
  • Page 49: Mechanical System

    Technical data 6.7 Mechanical system Mechanical system 6EP1333-3BA10 6EP1334-3BA10 6EP1336-3BA00 6EP1337-3BA00 (24 V/5 A) (24 V/10 A) (24 V/20 A) (24 V/40 A) Connection system Screw-type terminal Connections: Line input L1, N (L2), PE: 1 L1, N (L2), PE: 1 L1, N (L2), PE, Jump L1, N (L2), PE, Jump screw terminal each...
  • Page 50: Dimension Drawing

    Technical data 6.9 Dimension drawing Dimension drawing See Section Dimensions and weight (Page 18) CAD data that can be downloaded from the Internet: 6EP1333-3BA00 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00581) 6EP1334-3BA00 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00442) 6EP1336-3BA00 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00578) 6EP1337-3BA00 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00562) SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 51: Safety, Approvals, Emc

    Safety, approvals, EMC Safety 6EP1333-3BA10 (24 V/5 A) 6EP1334-3BA10 (24 V/10 A) 6EP1336-3BA00 (24 V/20 A) 6EP1337-3BA00 (24 V/40 A) Primary/secondary galvanic isolation Galvanic isolation SELV output voltage U acc. to EN 60950-1 and EN 50178 Protection class Class I Degree of protection (EN 60529) IP20 Leakage current, typ.
  • Page 52: Test Voltage

    Safety, approvals, EMC 7.2 Test voltage Test voltage Figure 7-1 Test voltage diagram Only the manufacturer can perform the type test and production test; users can also perform the field test. Preconditions for performing the field test: Tests (A) & (B) ●...
  • Page 53: Approvals

    Safety, approvals, EMC 7.3 Approvals Table 7- 2 Test voltages for 6EP1336-3BA00 and 6EP1337-3BA00 Test time Prim ↔ sec (A) Prim ↔ PE (B) Sec ↔ PE (C) Type test 60 s 4200 V DC 2200 V DC 700 V DC 60 s 3000 V AC 1500 V AC...
  • Page 54: Emc

    Safety, approvals, EMC 7.4 EMC 6EP1333-3BA10 (24 V/5 A) 6EP1334-3BA10 (24 V/10 A) 6EP1336-3BA00 (24 V/20 A) 6EP1337-3BA00 (24 V/40 A) Electrostatic discharge EN 61000-4-2 8 kV contact, 8 kV air Electromagnetic fields EN 61000-4-3 80 - 1000 MHz 25 V/m 1000 - 2700 MHz 10 V/m High-speed transient dis- EN 61000-4-4 4 kV at line supply connections...
  • Page 55: Ambient Conditions

    Ambient conditions 6EP1333-3BA10 (24 V/5 A) 6EP1336-3BA00 (24 V/20 A) 6EP1334-3BA10 (24 V/10 A) 6EP1337-3BA00 (24 V/40 A) Ambient temperature -25 ... 70 °C for natural convection (self 0 … 70 °C for natural convection (self con- convection) vection) Tested according to: EN 60068-2-1 cold •...
  • Page 56 Ambient conditions SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 57: Applications

    Applications Parallel connection to increase power rating To increase the power rating, power supplies of the same type can be directly connected in parallel. The following must be observed: ● The cables connected to each power supply at terminals "+" and "-" must have identical lengths and the same cable cross-sections (or the same impedance) up to a common external connection point (terminal strip) if possible.
  • Page 58 Applications 9.1 Parallel connection to increase power rating Note It is not permissible to take into account simultaneous overload capability (Extra-Power 150% for 5 s/min) of several power supplies connected in parallel when configuring the power supply system. NOTICE Protective circuit for the parallel connection of more than two power supplies When connecting more than two power supplies in parallel, additional measures must be taken to prevent high reverse currents in the event of a secondary device fault.
  • Page 59: Parallel Connection For Redundancy

    Applications 9.2 Parallel connection for redundancy Parallel connection for redundancy Connecting several 24 V power supplies in parallel for redundancy purposes is required if especially high demands are placed regarding the availability of a reliable 24 V power supply. Using the SITOP PSE202U redundancy module, two power supplies of the same type up to 20 A can be decoupled (Figure 9-2 Redundant configuration with two power supplies and SITOP PSE202U redundancy module (Page 59)).
  • Page 60 Applications 9.2 Parallel connection for redundancy You can find additional information at: SITOP PSE202U manual (https://support.industry.siemens.com/cs/ww/en/view/42248598) SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 61: Series Connection For Increased Voltage

    ±24 V or -48 V can be realized. Note For additional details, see Catalog KT 10.1 Chapter 15 Technical information and configuring (see http://w3app.siemens.com/mcms/infocenter/content/en/Pages/order_form.aspx?nodeKey=ke y_518431&infotype=catalogs). WARNING SELV is not guaranteed in the case of a fault When connecting two power supplies in series, the continuous, permissible SELV voltage of a maximum of 60 VDC according to EN 60950-1 cannot be guaranteed in the case of a fault.
  • Page 62: Overload Protection In The 24 V Output Circuit

    SIMATIC S7-1200/1500/300/400, for STEP 7 Classic and TIA Portal at no charge. You can find additional information at: Manual SITOP selectivity modules (https://support.industry.siemens.com/cs/ww/en/view/108989004) Figure 9-5 Electronic protection of 24 V loads using the SITOP PSE200U selectivity module SITOP modular 1ph/2ph...
  • Page 63: Protection Against Short-Time Voltage Dips

    5 A. This time can be increased a multiple number of times by connecting buffer modules in parallel; the maximum buffer time is 10 s. You can find additional information at: SITOP PSE201U manual (https://support.industry.siemens.com/cs/ww/en/view/41129219) Figure 9-6 Buffering brief power failures using the SITOP PSE201U buffer module SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 64: Protecting Against Longer Power Failures

    Using the free-of-charge SITOP DC-UPS software tool, DC-UPS systems can be simply integrated into PC-based automation solutions. This supports further processing of the status signals and safely running down the PC. You can find additional information at: Manual, DC UPS with capacitors (http://support.automation.siemens.com/WW/view/en/48932766/133300) SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 65 – make it easy to integrate operating and diagnostics information into STEP 7 user programs. Preconfigured UPS faceplates for WinCC visualization can be downloaded at no charge. You can find additional information at: DC UPS SITOP UPS1600/UPS1100 Manual (http://support.automation.siemens.com/WW/view/en/84977415) SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 66 Applications 9.6 Protecting against longer power failures SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 67: Environment

    Environment The devices are in conformance with RoHS. As a rule, only non-silicon precipitating materials are used. Disposal guidelines Packaging and packaging aids can and should always be recycled. The product itself may not be disposed of as domestic refuse. SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 68 Environment SITOP modular 1ph/2ph Manual, 04.2018, C98130-A7548-A1-4-7629...
  • Page 69: Service & Support

    Technical support for all IA/DT products can be accessed through the following communication channels: ● Telephone: + 49 (0) 911 895 7222 ● Internet: Web form for support request (http://www.siemens.de/automation/support-request) Technical documentation on the Internet Operating instructions and manuals for SITOP are available in the Internet: Operating instructions/manuals (http://www.siemens.com/sitop/manuals)
  • Page 70 Service & Support Contact persons If you have any questions regarding the use of our products, then contact the Siemens contact person in your regional Siemens sales office. You can find these addresses as follows: ● On the Internet (http://www.automation.siemens.com/partner) ●...