ECODRIVE DKC02.1 Drive Controller
3.3
Compiling the required data
Mounted mechanical system
Motor data
Line conditions
DOK-ECODRV-DKC02.1****-PRJ2-EN-P
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Designation
Effective load torque
data
Acceleration torque
Operating torque
Motor speed used
Load moment of inertia
(reduced to motor shaft)
Maximum rotary energy in the
mechanical system (E-stop case)
Continuous regenerative power
Motor/controller combination
Continuous torque at standstill
Maximum torque
Short-term operation torque
Motor inertia
Maximum motor speed
Power consumption of the motor
holding brake (if present)
Refer to the project planning
manual MKD Motors
Required power line connection
Required rated line voltage
DKC current consumption
Fig. 3-2: Data required for selecting the components
Selecting the components
Symbol
Values/Units
M
EFF
.............................. in Nm
M
ACC
.............................. in Nm
M
BEARB
.............................. in Nm
n
NUTZ
.............................. in min-1
J
LAST
.............................. in kgm²
W
ROT,MAX
.............................. in Ws
P
RD
.............................. in kW
DKC...................................
MKD...................................
M
DN
.............................. in Nm
M
MAX
............................. in Nm
M
KB
............................. in Nm
J
M
............................. in kgm²
n
MAX
............................. in min-1
I
N,HB
............................. in A
S
AN
............................. in kVA
U
N
............................. in V
I
N,DC
0.7
3-3
in A