4-14
ECODRIVE DKC drive controllers
X8 power connection
X9 DC bus connection
X10/X11 SERCOS interface connection
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Maximum wire cross section that can be connected: 4 mm
Line input voltage: 3 x AC 380 ... 480 V (± 10%), 50 ... 60 Hz
Maximum wire cross section that can be connnected: 4 mm
DC bus connection for connecting:
an auxiliary bleeder module BZM01.1
- or -
an auxiliary capacitance module CZM01.1
- or -
additional DKC drive controllers
For connection assignments, please refer to the overall connection dia-
gram Fig. 4-13. The connection diagrams are located with the respective
additional components.
X10: Tx, transmitter
When planning the fiber optic cable ring, please consult the description
"Fiber Optic Cable - Handling" (see pg. 3 of the supplementary docu-
mentation). In it you will find a list of fiber optic plugs, cables and accesso-
ries.
The fiber optic plugs for X10 and X11 are not included in the drive con-
troller.
ECODRIVE DKC02.1 Drive Controller
X11: Rx, receiver
DOK-ECODRV-DKC02.1****-PRJ2-EN-P
2
2