hit counter script

X8 Power Connection; X9 Dc Bus Connection; X10/X11 Sercos Interface Connection - Bosch Rexroth Indramat ECODRIVE DKC02.1 Series Project Planning Manual

Drive controller
Table of Contents

Advertisement

4-14
ECODRIVE DKC drive controllers

X8 power connection

X9 DC bus connection

X10/X11 SERCOS interface connection

LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Maximum wire cross section that can be connected: 4 mm
Line input voltage: 3 x AC 380 ... 480 V (± 10%), 50 ... 60 Hz
Maximum wire cross section that can be connnected: 4 mm
DC bus connection for connecting:
an auxiliary bleeder module BZM01.1
- or -
an auxiliary capacitance module CZM01.1
- or -
additional DKC drive controllers
For connection assignments, please refer to the overall connection dia-
gram Fig. 4-13. The connection diagrams are located with the respective
additional components.
X10: Tx, transmitter
When planning the fiber optic cable ring, please consult the description
"Fiber Optic Cable - Handling" (see pg. 3 of the supplementary docu-
mentation). In it you will find a list of fiber optic plugs, cables and accesso-
ries.
The fiber optic plugs for X10 and X11 are not included in the drive con-
troller.
ECODRIVE DKC02.1 Drive Controller
X11: Rx, receiver
DOK-ECODRV-DKC02.1****-PRJ2-EN-P
2
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth indramat ecodrive dkc02.1-040-7-fw

Table of Contents