Status
Safe brake close active
r9773.4
Close brake selected
r0899.13
Settings
Setting
Safe brake control
p9602
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB
6.6 Configuring safety functions integrated in the drive
Meaning
Display and BICO output for the status of Safety Integrated on the drive
(Control Unit + Motor Module):
SBC requested
Display and BICO output for the status word of the sequence control:
Command, close holding brake
Meaning
Sets the enable signal for the "Safe brake control" (SBC) function on the
Control Unit.
● [0] Inhibit SBC
● [1] Enable SBC
Commissioning and configuring