Functions
8.3 Web server
Activity monitoring
The activity on the web server is monitored. If the web server has master control and over an
adjustable period of time (default: 30 minutes) no activity is detected, the web client connection
is automatically logged off. The connection termination means that control no longer lies with
the Web server, and the 3RW55 or 3RW55 Failsafe soft starter stops the motor if it is switched on.
The following activities are considered by the web server in terms of activity monitoring:
• Clicking on buttons in the following areas or web pages (Page 100):
– Menu
– Header
– Alarm line
– "Control Panel" web page
• Clicking the button "Automatic logout in ... minute(s). Click to reset the timer."
This button is visible in the footer of the web pages if you are logged on to the web server.
You can set the timer to 30 min (default), or by the hour to 1 ... 10 hours.
8.3.6.1
Logging on to the web server
Requirements
• User account with the "Operator personnel" or "Maintenance personnel" user role
For more information on user account management, refer to the 3RW55 and 3RW55 Failsafe
Soft Starters Equipment Manual. Functions for monitoring and diagnosis are possible
without logon.
• Valid certificate (Page 96)
• Secured https connection, e.g. https://192.168.1.1
98
SIRIUS 3RW5 PROFINET communication modules
Equipment Manual, 05/2021, A5E35631297002A/RS-AD/004