Operation Without Pn Control - Siemens PROFINET SIRIUS 3RW5 Equipment Manual

Soft starters and solid-state switching devices
Hide thumbs Also See for PROFINET SIRIUS 3RW5:
Table of Contents

Advertisement

Displayed name and level
1s
2n
3rd level
t
d
Active power
Asymmetry
Motor temperature rise
Phase current I L1 (%)
Phase current I L2 (%)
Phase current I L3 (%)
Power factor L1...3
Remaining motor cooling time
Remaining time for motor overload
protection
Statistics
Active energy import total
Last tripping current IA (%)
Number of motor overload trips
Number of starts motor CCW
Number of starts motor CW
Operating hours - device
Operating hours - motor
Phase current max (%)
8.5

Operation without PN control

The parameter "Operation without PN control" determines how the 3RW55 and 3RW55 Failsafe
soft starters behave in relation to a PLC. The parameter is only relevant in connection with the
use of the web server or OPC UA server.
Requirement
• 3RW5 PROFINET High Feature communication module from firmware version V2.0
• Soft starter 3RW55 with firmware version V2.1.1 or higher or soft starter 3RW55 Failsafe with
firmware version V1.1.0 or higher
SIRIUS 3RW5 PROFINET communication modules
Equipment Manual, 05/2021, A5E35631297002A/RS-AD/004
Tag
Browse name
Active_Power_P
Phase_Unbalance
Thermal_Memory
Current_I_L1
Current_I_L2
Current_I_L3
Cos_Phi
Cooling_Down_Period
Time_to_Trip
Statistics
Consumed_Energy
Last_Trip_Current
Number_of_Overload_Trips
Int_Number_of_reverse_Starts
Int_Number_of_direct_Starts
Device_Operating_Hours
Motor_Operating_Hours
Max_Current_I_max
8.5 Operation without PN control
NodeId.
Data format Unit
Identifier
i =
51
UInt32
31
Byte
30
Byte
34
UInt16
35
UInt16
36
UInt16
32
Byte
39
UInt16
38
UInt16
2
-
92
UInt32
37
UInt16
73
UInt16
91
UInt32
90
UInt32
88
UInt32
86
UInt32
33
UInt16
Functions
W
%
%
%
%
%
%
s
s
-
kWh
%
-
-
-
s
s
%
135