Mounting and dismantling
4.2 Removing the 3RW5 communication module from the 3RW5 soft starter
4.2
Removing the 3RW5 communication module from the 3RW5 soft
starter
Requirements
• 3RW52, 3RW55 or 3RW55 Failsafe soft starters
• Removed bus connector (Page 51)
• Screwdriver PH1
• Slotted screwdriver with blade width 5.5 to 8 mm
NOTICE
Damage to property due to electrical voltage
Switch off the power to the 3RW5 soft starter before starting work (main and control supply
voltage).
Note
A magnetic screwdriver simplifies disassembly.
Procedure
NOTICE
Damage to property
Ensure that no foreign matter can get into the slot.
40
SIRIUS 3RW5 PROFINET communication modules
Equipment Manual, 05/2021, A5E35631297002A/RS-AD/004