ST950 Plus+ User Manual
4.9.2
Smartloop Cable Connections
The following descriptions relate to the connections made within the Torpedo resin joints. Other
cable jointing methods are also available.
The Plus+ street cables are to be fitted with CET gland and jubilee glands. This is the case for both
upstream (to/from the RAG Node) and downstream to subsequent Smartloops.
Figure 55 : Termination of Street Cable Armouring
If there is only one Smartloop linked to the upstream node, the earth cable available from the
Smartloop Plus+ Network cable is terminated at the CET gland.
If multiple Smartloops to be linked together then an additional earth wire will be required to bridge
the two CET glands.
Figure 56 : Smartloop Plus+ Network Connection Detail
ST950 Plus+ User Manual
Spur Connection
(E.g. RAG Node)
CET
Plus+ Network Cable (Smartloop)
CET
Earth
CET
Plus+ Network Cable (Smartloop)
Earth
Page 97 of 176
667/HE/53000/000
Smartloop Plus+
Street Cable
Network Cable
D+
D+
D-
D-
+48VDC
+48VDC
0V
0V
D+ (downs tream connection)
D- (d ownstream connection )
Earth
Smartloop
Smartloop #2
Issue 2
Unrestricted