Print Mode
Dividing the parameters into seven parameter blocks has the advantage that you
only need to assign parameters to the block which deviates from the default
values. However, this parameter block must be entered complete even if
individual parameters within the block are to retain their default values. If the
value entered exceeds the limit value, this value is automatically replaced by the
limit value.
•
The low limit is used if the value entered is below this value.
•
The high limit is used if the value entered exceeds this value.
Example: Example Input: Lines per page "10
Input: left margin "80
Entering the parameter blocks
You must first enter all the parameter blocks you want to change in DB 1 using
the programmer. Then transfer DB1 to the memory submodule.
Note:
Proceed as follows to change a DB in the memory submodule:
1. Transfer total contents of the memory submodule from the memory
submodule to the programmer (diskette, hard disk)
2. Delete memory submodule
3. Change DB
4. Transfer total memory contents back to the memory submodule
6-6
" is replaced by "20
H
" is replaced by "3C
"
H
H
CP 521
"
H
GWA 4NEB 812 6030-02b