Square hole
processed on
the flue pipe
Attentions!
Please extend the flue pipe out of the wall 30mm if the flue pipe
extends out of the wall directly.
One straight and short flue pipe can make the cooker hood
discharge the smoke more fluently.
Avoid the overlong flue pipe as far as possible, and reduce the
quantity of bending angles of the flue pipe as far as possible,
because these factors may affect the exhausting effect of the
cooker hood.
The flue pipe cannot be installed with following method, in order
not to affect the exhausting effect.
The ceiling space shall facilitate installation of the flue pipe and
cannot hinder arrangement of the flue pipe; and the recommended
space is 300mm and above.
The recommended distance between the cooker hood and the
supporting surface of the cooker is 750mm and below during
installation because the exhausting effect may be affected if the
installation height is too great.
Installation of flue pipe base
Fix th e air outlet base on the top of the cooker hood with
four M4 *14 tapping screws.
Air outlet base
Screw
M4x14
Central line of
Wall
the cooker hood
Sleeve 6-inch aluminium flue pipe on the air outlet base; pull the
pipe with the needed length and fix the pipe orifice to the location of
exhaust outlet; if the flue pipe is 5 inches only, sleeve another air
outlet base having narrow orifice on the air outlet base.
Arrange the flue pipes neatly and flatly in order to ensure smooth
exhausting. In order to strengthen the exhausting efficiency of the
cooker hood, the flue pipe shall not be too long, and optimal
length thereof shall be 1-1.8m; and the bending angle shall be
great as far as possible and avoid buckling.
The orifice of the flue pipe outside the door shall be slanted down
in order to prevent the cooker hood from damage due to
backflow of rainwater.
DO NOT let the gas exhausted by the cooker hood contact
with other exhausting pipes of combustible gas or any flue, or let
the gas discharged flow back to the room.
Connection of flue pipe
The exhaust pipe is fixed on the air outlet base, please use the
glass glue to stabilize the interface position, and then wrapped
with aluminum foil tape seal.
Air outlet
base
Installation of oil cup
Install the oil cup into the neck of the protective screen, as shown
in the figure.
oil cup
Test run
Please clean the surface of the cooker hood upon completion
of installation; then plug the power plug of the cooker hood to
the socket, and implement test run in accordance with the contents
in "Operating instruction" after waiting for about 3 seconds.
Instruction for installation EN
Flue pipe having outer