Installation
How to Install the Unit
1. To prevent vibration and noise, make sure the
unit is installed securely and firmly
2. Install the unit where the sunlight does not
shine directly on the unit.
3. The outside of the cabinet must extend outward
for at least 14" and there should be no
obstacles, such as a fence or wall, within 20"
from the back of the cabinet because it will
prevent heat radiation of the condenser.
Restriction of outside air will greatly reduce the
cooling efficiency of the air conditioner.
NOTICE
All side louvers of the cabinet must remain exposed to the outside of the structure.
4. Install the unit at a slight incline so the back is slightly lower than the front(about 1/4").
This will force condensed water to flow to the outside.
5. Install the unit with the bottom about 30"~60" above the floor level.
Installing the Power cord
You can choose between the two methods below according to your preference and window sill
shape.
Using slit "A"
• Fasten the stopper using Type A screw, and
pass the power cord through slit "A".
Screw (Type A)
Power cord
12 Room Air Conditioner
°C
Cooled air
• Fasten the stopper using left screw hole, and
rotate properly to pass the power cord through
slit "B".
Screw (Type A)
A
Power cord
Awning
Heat
radiation
About
1
/
"
4
Over 20"
Using slit "B"
°C
Fence
B