Note: Since the base stores all work group settings and transfers to them to scanner once
they are linked, changes are typically done to the base and not to the scanner.
Tag
SubTag
Data
Storage
Query Commands
Several special characters can be used to query the device about its settings.
^
?
*
:Name: Field Usage (Optional)
This command returns the query information from the scanner.
Tag Field Usage
When a query is used in place of a Tag field, the query applies to the entire set of
commands available for the particular storage table indicated by the Storage field
of the command. In this case, the SubTag and Data fields should not be used
because they are ignored by the device.
172
scanner is Voyager_1472 scanner. This setting is changed by using
the BT_NAM command, which accepts alphanumeric values. If the
name is not known, a wildcard (*) can be used :*:.
A 3 character case-insensitive field that identifies the desired menu
command group. For example, all RS232 configuration settings are
identified with a Tag of 232.
A 3 character case-insensitive field that identifies the desired menu
command within the tag group. For example, the SubTag for the
RS232 baud rate is BAD.
The new value for a menu setting, identified by the Tag and SubTag.
A single character that specifies the storage table to which the com-
mand is applied. An exclamation point (!) performs the command's
operation on the device's volatile menu configuration table. A period
(.) performs the command's operation on the device's non-volatile
menu configuration table. Use the non-volatile table only for semi-
permanent changes you want saved through a power cycle.
What is the default value for the setting(s).
What is the device's current value for the setting(s).
What is the range of possible values for the setting(s). (The device's
response uses a dash (-) to indicate a continuous range of values. A
pipe (|) separates items in a list of non-continuous values.)
Voyager XP User Guide