hit counter script

Ack/Nak; Scanner To Bioptic Communication; Scanner-Bioptic Packet Mode - Honeywell Voyager 147 Series User Manual

Area-imaging scanner
Table of Contents

Advertisement

ACK/NAK

After transmitting data, the scanner waits for an ACK character (hex 06) or a NAK
character (hex 15) response from the host. If ACK is received, the communications
cycle is completed and the scanner looks for more barcodes. If NAK is received, the
last set of barcode data is retransmitted and the scanner waits for ACK/NAK again.
Turn on the ACK/NAK protocol by scanning the ACK/NAK On barcode below. To
turn off the protocol, scan ACK/NAK Off. Default = ACK/NAK Off.

Scanner to Bioptic Communication

The following settings are used to set up communication between Honeywell
scanners and bioptic scanners.
Note: The scanner's baud rate must be set to 38400 and the RS232 timeout must be set to
3000 in order to communicate with a bioptic scanner. See "RS232 Baud Rate" on
page 31, and

Scanner-Bioptic Packet Mode

Packet Mode On must be scanned to set the scanner's format so it is compatible
with a bioptic scanner. Default = Packet Mode Off.
Voyager XP User Guide
ACK/NAK On
RS232 Timeout
* Packet Mode Off
on page 34 for further information.
* XON/XOFF Off
* ACK/NAK Off
Packet Mode On
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Voyager 1470gVoyager 1472g

Table of Contents