The formatted logical information is updated and the window displays.
Table 7.2
Formatting Message
Displayed
02-xxxx, 03-xxxx, 04-xxxx or 0B-xxxx
05-xxxx
05-2500 or 05-2581
05-2600
05-2580
0B-FD01
DMEA000006 or DMEA000007
128
Chapter 7 Configuring Storage on the Thunder 9530™ V Series Subsystem
Action to be Taken
For the above code, a hardware fault is assumed. If the fault is not recovered
after re-execution, contact Acer | HDS.
For the above code, an operation error is assumed. Upon checking the
following items and re-execute processing. If the error is not recovered,
contact Acer | HDS.
Is logical unit 0 defined?
In spite of none of drive mounted states, is ALL RAID specified and is a
logical unit specified for ALL CAPA formatted?
Is an attempt made to define a logical unit exceeding the capacity of the
defined RAID group?
Switching a controller in charge of a logical unit occurred during formatting.
Check the controller in charge and re-execute formatting from the controller
in charge.
Drive failure recovery or ShadowImage-In-System Replication, and/or Copy-
on-Write Snapshot may be in operation. Check the status of the subsystem.