Table 4. SPCN Error Codes (continued)
Error Code Description
1021 2603 Power domain fault in secondary I/O
drawer
1021 2612 SPCN problem
1021 3100 I2C controller fault
1021 3101 I2C bus 1 fault
1021 3102 I2C bus 2 fault
1021 3104 I2C bus 4 fault
1021 3105 I2C bus 5 fault
1021 3113 RIO bus adapter fault
1021 3114 PCI backplane fault
1021 3115 Operator panel fault
1021 3116 Fan controller fault
1021 3118 Backplane fault
1021 311C Secondary I/O thermal sensor fault
Action/
Possible Failing FRU
1. Secondary I/O drawer power
supply
Locations:
U0.2-V1
U0.2-V2
2. Secondary I/O backplane
Location: U0.2-P1
Secondary I/O backplane
Location: U0.2-P1
Secondary I/O backplane
Location: U0.2-P1
1. Secondary I/O operator panel
Location: U0.2-L1
2. Secondary I/O backplane
Location: U0.2-P1
Secondary I/O backplane
Location: U0.2-P1
Secondary I/O backplane
Location: U0.2-P1
1. Secondary I/O fan controller
card
Location: U0.2-L1
2. Secondary I/O backplane
Location: U0.2-P1
RIO bus adapter
Location: U0.2-P1.1
Secondary I/O PCI backplane
Location: U0.2-P1
Operator panel
Location: U0.2-L1
1. Fan controller card
Location: U0.2-X2
2. Secondary I/O backplane
Location: U0.2-P1
Secondary I/O backplane
Location: U0.2-P1
1. Secondary I/O operator panel
Location: U0.2-L1
2. Secondary I/O backplane
Location U0.2-P1
Chapter 5. Error Code to FRU Index