hit counter script

IBM NetVista 6058 Hardware Maintenance Manual page 171

Computer types
Table of Contents

Advertisement

POST Error Code
6XXNot listed above
762Math coprocessor configuration error
7XX Not listed above
962 Parallel port configuration error
9XX
1047
107XCheck SCSI terminator installation
1101Serial connector error, possible system board
failure
1101, 1102, 1106, 1108, 1109
1107
1102Card selected feedback error
1103Port fails register check
1106Serial option cannot be turned off
FRU/Action
1. Diskette Drive
2. System Board
3. External Drive Adapter
4. Diskette Drive Cable
5. Power Supply
1. Run Setup
2. Processor
3. System Board
1. Processor
2. System Board
1. Run Configuration
2. Parallel Adapter (if installed)
3. System Board
1. Printer
2. System Board
1. 16-Bit AT Fast SCSI Adapter
1. Check SCSI terminator installation
2. SCSI Cable
3. SCSI Terminator
4. SCSI Device
5. SCSI Adapter
1. Run Enhanced Diagnostics
1. System Board
2. Any Serial Device
1. Communications Cable
2. System Board
1. Run Enhanced Diagnostics
1. Run Enhanced Diagnostics
2. System Board
1. Run Enhanced Diagnostics
2. System Board