Error messages
Error codes appear in the status display area when an error
(usually a hardware problem) occurs. In addition, both
error messages and error codes appear on the video
monitor screen or on a PC monitor connected to the
MONITOR connector.
When an error message appears, follow the instructions in
the error message to resolve the problem.
Example error code in status display area
Error code
Example error message in video monitor
Error code
Specifications
General
External dimensions (w/h/d, excluding projections)
424 × 132 × 460 mm (16
1
18
/
inches)
8
Mass
XDS-PD1000: 17 kg (37 lb. 7.7 oz.)
XDS-PD2000: 16 kg (35 lb. 4.4 oz.)
Power requirements
90 V to 264 V AC, 47 Hz to 63 Hz
Power consumption
XDS-PD1000: 190 W
XDS-PD2000: 210 W
Inrush current
(1) Maximum possible inrush current at
initial switch-on (Voltage changes
caused by manual switching): 32 A
peak, 7 A r.m.s. (240 V AC)
(2) Inrush current after a mains
interruption of five seconds (Voltage
changes caused at zero-crossing):
13 A peak, 5 A r.m.s. (240 V AC)
Operating temperature
5ºC to 40ºC (41ºF to 104ºF)
Storage temperature
–20ºC to +60ºC (–4ºF to +140ºF)
Operating relative humidity
20% to 90%
3
1
/
× 5
/
×
4
4
in mm (inches)
147
Specifications