Sign In
Upload
Manuals
Brands
IBM Manuals
Server
BladeCenter PS704
IBM BladeCenter PS704 Manuals
Manuals and User Guides for IBM BladeCenter PS704. We have
2
IBM BladeCenter PS704 manuals available for free PDF download: Service Manual, Technical Overview And Introduction
IBM BladeCenter PS704 Service Manual (298 pages)
7891-73X;7891-74X
Brand:
IBM
| Category:
Server
| Size: 7.67 MB
Table of Contents
Table of Contents
5
Safety Notices
7
Chapter 1. Introduction
13
Related Documentation
13
Notices and Statements
14
Features and Specifications
14
Supported Dimms
16
Blade Server Control Panel Buttons and Leds
18
Turning on the Blade Server
19
Turning off the Blade Server
20
System-Board Layouts
20
System-Board Connectors
21
System-Board Leds
24
Chapter 2. Diagnostics
27
Diagnostic Tools
27
Collecting Dump Data
29
Location Codes
29
Reference Codes
32
System Reference Codes (Srcs)
33
1Xxxyyyy Srcs
34
6Xxxyyyy Srcs
45
A1Xxyyyy Service Processor Srcs
48
AA00E1A8 to AA260005 Partition Firmware Attention Codes
49
B1Xxyyyy Service Processor Srcs
52
B200Xxxx Logical Partition Srcs
52
B7Xxyyyy Licensed Internal Code Srcs
62
BA000010 to BA400002 Partition Firmware Srcs
73
POST Progress Codes (Checkpoints)
109
C1001F00 to C1645300 Service Processor Checkpoints
110
C2001000 to C20082FF Virtual Service Processor Checkpoints
118
IPL Status Progress Codes
127
C700Xxxx Server Firmware IPL Status Checkpoints
127
CA000000 to CA2799FF Partition Firmware Checkpoints
127
D1001Xxx to D1Xx3Fff Service Processor Dump Codes
145
D1Xx3Y01 to D1Xx3Yf2 Service Processor Dump Codes
150
D1Xx900C to D1Xxc003 Service Processor Power-Off Checkpoints
153
Service Request Numbers (Srns)
154
Using the SRN Tables
154
101-711 through FFC-725 Srns
154
A00-FF0 through A24-XXX Srns
181
SCSD Devices Srns (Ssss-102 to Ssss-640)
181
Failing Function Codes
185
Error Logs
188
Checkout Procedure
188
About the Checkout Procedure
188
Performing the Checkout Procedure
189
Verifying the Partition Configuration
191
Running the Diagnostics Program
191
Starting AIX Concurrent Diagnostics
191
Starting Stand-Alone Diagnostics from a CD
191
Starting Stand-Alone Diagnostics from a NIM Server
192
Using the Diagnostics Program
193
Boot Problem Resolution
194
Troubleshooting Tables
195
General Problems
195
Drive Problems
196
Intermittent Problems
196
Management Module Service Processor Problems
197
Memory Problems
197
Microprocessor Problems
198
Network Connection Problems
198
PCI Expansion Card (PIOCARD) Problem Isolation Procedure
198
Optional Device Problems
200
Power Problems
200
Hypervisor Problems
202
Service Processor Problems
205
Software Problems
221
Universal Serial Bus (USB) Port Problems
222
Light Path Diagnostics
222
Viewing the Light Path Diagnostic Leds
222
Light Path Diagnostics Leds
225
Isolating Firmware Problems
228
Recovering the System Firmware
229
Starting the PERM Image
229
Starting the TEMP Image
229
Recovering the TEMP Image from the PERM Image
230
Verifying the System Firmware Levels
230
Committing the TEMP System Firmware Image
231
Solving Shared Bladecenter Resource Problems
231
Solving Shared Media Tray Problems
232
Solving Shared Network Connection Problems
233
Solving Shared Power Problems
234
Solving Undetermined Problems
235
Calling IBM for Service
236
Chapter 3. Parts Listing, Type 7891
237
Chapter 4. Removing and Replacing Blade Server Components
241
Installation Guidelines
241
System Reliability Guidelines
242
Handling Static-Sensitive Devices
242
Returning a Device or Component
242
Removing the Blade Server from a Bladecenter Unit
243
Installing the Blade Server in a Bladecenter Unit
244
Removing and Replacing Tier 1 Crus
245
Removing the Blade Server Cover
245
Installing and Closing the Blade Server Cover
247
Removing the Expansion Unit for a PS704 Blade Server
249
Replacing the Expansion Unit in a PS704 Blade Server
250
Removing the Bezel Assembly
252
Installing the Bezel Assembly
253
Removing a Hard-Disk Drive
254
Installing a Hard-Disk Drive
255
Removing an SSD Carrier
256
Replacing an SSD Carrier
257
Removing an SSD
258
Installing an SSD
260
Removing a Memory Module
261
Installing a Memory Module
263
Removing and Installing an I/O Expansion Card
265
Removing a Ciov Form-Factor Expansion Card
266
Installing a Ciov Form-Factor Expansion Card
267
Removing a Combination-Form-Factor Expansion Card
268
Installing a Combination-Form-Factor Expansion Card
269
Removing the Battery
270
Installing the Battery
270
Removing the Disk Drive Tray
272
Installing the Disk Drive Tray
273
Removing the Tier 2 Management Card
274
Installing the Tier 2 Management Card
275
Replacing the FRU System-Board and Chassis Assembly
276
Chapter 5. Configuring
279
Updating the Firmware
279
Configuring the Blade Server
281
Using the SMS Utility
281
Starting the SMS Utility
281
SMS Utility Menu Choices
282
Creating a CE Login
282
Configuring the Gigabit Ethernet Controllers
282
Blade Server Ethernet Controller Enumeration
283
MAC Addresses for Integrated Ethernet Controllers
284
Configuring a RAID Array
285
Updating IBM Director
285
Appendix. Notices
287
Trademarks
288
Electronic Emission Notices
289
Class a Notices
289
Class B Notices
293
Terms and Conditions
296
Advertisement
IBM BladeCenter PS704 Technical Overview And Introduction (198 pages)
Brand:
IBM
| Category:
Server
| Size: 7.26 MB
Table of Contents
Front Cover
1
Table of Contents
5
Notices
9
Trademarks
10
Preface
11
The Team Who Wrote this Paper
11
Comments Welcome
13
Now You Can Become a Published Author, too
13
Stay Connected to IBM Redbooks
13
Chapter 1. Introduction and General Description
15
Overview of PS703 and PS704 Blade Servers
16
Comparison between the Ps70X Blade Servers
17
IBM Bladecenter Chassis Support
18
Supported Bladecenter Chassis
19
Number of PS703 and PS704 Blades in a Chassis
26
Operating Environment
26
Physical Package
27
System Features
28
PS703 System Features
28
PS704 System Features
30
Minimum Features for the POWER7 Processor-Based Blade Servers
32
Power Supply Features
33
Processor
34
Memory Features
34
I/O Features
35
Disk Features
40
Standard Onboard Features
40
Supported Bladecenter I/O Modules
42
Ethernet Switch and Intelligent Pass-Through Modules
42
SAS I/O Modules
43
Fibre Channel Switch and Pass-Through Modules
44
Converged Networking I/O Modules
45
Infiniband Switch Module
46
Multi-Switch Interconnect Module
47
Multi-Switch Interconnect Module for Bladecenter HT
48
Building to Order
48
Model Upgrades
49
Chapter 2. Architecture and Technical Overview
51
Architecture
52
The IBM POWER7 Processor
53
POWER7 Processor Overview
54
POWER7 Processor Core
55
Simultaneous Multithreading
56
Memory Access
57
Flexible POWER7 Processor Packaging and Offerings
57
On-Chip L3 Intelligent Cache
58
POWER7 Processor and Intelligent Energy
60
Comparison of the POWER7 and POWER6 Processors
60
POWER7 Processor-Based Blades
61
Memory Subsystem
61
Memory Placement Rules
62
Active Memory Expansion
66
Technical Comparison
68
Internal I/O Subsystem
69
PCI Express Bus
70
Pcie Slots
70
I/O Expansion Cards
75
Embedded SAS Controller
77
Embedded Ethernet Controller
77
Embedded USB Controller
78
Service Processor
79
Server Console Access by SOL
79
Anchor Card
81
Internal Storage
82
Hardware RAID Function
86
External SAS Connections
87
External Disk Subsystems
87
IBM Bladecenter S Integrated Storage
87
IBM System Storage
93
IVM
95
Operating System Support
97
IBM Energyscale
99
IBM Energyscale Technology
100
Energyscale Device
102
Chapter 3. Virtualization
103
Powervm Version 2.2 Enhancements
104
POWER Hypervisor
106
POWER Processor Modes
110
Powervm
111
Powervm Editions
112
Logical Partitions
113
Multiple Shared-Processor Pools
116
Vios
122
Powervm Lx86
126
Powervm Live Partition Mobility
126
Active Memory Sharing
128
Suspend/Resume
129
N_Port ID Virtualization (NPIV)
130
Supported Powervm Features by Operating System
131
Chapter 4. Continuous Availability and Manageability
133
Introduction
134
Reliability
134
Designed for Reliability
135
Placement of Components
135
Redundant Components and Concurrent Repair
135
Availability
135
Partition Availability Priority
136
General Detection and Deallocation of Failing Components
136
Memory Protection
138
Cache Protection
141
Special Uncorrectable Error Handling
142
PCI Extended Error Handling
143
Serviceability
143
Detecting
145
Diagnosing
148
Reporting
149
Notifying the Client
150
Locating and Servicing Parts Requiring Service
151
Manageability
155
Service User Interfaces
155
IBM Power Systems Firmware Maintenance
158
Electronic Service Agent and Service and Support Manager
161
Bladecenter Service Advisor
162
Chapter 5. Systems Director Management Console
165
SDMC Introduction
166
Hardware Appliance
166
Software Appliance
166
IVM, HMC, and SDMC Support
166
Terminology
168
Using the Web Interface
168
Resources Tab
170
Settings Tab
171
POWER-Based Blades Management
171
IVM Characteristics
171
SDMC Added Capability for POWER-Based Blades
172
IVM to SDMC Transition
172
IVM to SDMC Transition Process
173
Steps to SDMC Management of POWER-Based Blades
174
FSP Access Configuration from Bladecenter AMM
174
Discovery
175
Request Access to Server
176
Updating ASM Passwords
177
Systems Director Inventory Collection
178
SDMC Basic Management of POWER-Based Blades
179
Virtual Server Creation
180
Multiple Profiles for POWER-Based Blades
185
Dual VIOS on POWER-Based Blades
187
Virtual Server Suspend and Resume
189
Active Memory Expansion (AME)
190
Virtual Consoles from the SDMC
191
Abbreviations and Acronyms
193
Related Publications
195
IBM Redbooks Documents
195
Other Publications
195
Online Resources
196
How to Get Redbooks
196
Help from IBM
196
Advertisement
Related Products
IBM PS700
IBM BladeCenter PS703
IBM BladeCenter PS701
IBM BladeCenter PS702
IBM p Series 680 Model S85
IBM System p Series
IBM PS0
IBM PSV
IBM Power 755
IBM p5 595
IBM Categories
Server
Desktop
Storage
Laptop
Monitor
More IBM Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual