RM-25
Nokia Customer Care
RF troubleshooting
Measuring the synthesizer manually using spectrum analyzer
Figure 145 Troubleshooting chart for synthesizer
Spectrum analyzer level values depend on the probe type and should be validated using a known good sample.
The levels that are given here are measured using a high frequency probe. Spectrum analyzer should be at least
capable of measuring signal upto 4.5 GHz.
Page 7–44
Company Confidential
9235618 (Issue 2)