10.3

Data Setting for JOG Operation

To execute JOG operation, certain data must be set and stored in the buffer memory areas.
The following table lists the JOG data to be set, setting condition, and check timing.
Setting item
JOG speed
Cd.3
Speed limit value
Pr.5
Acceleration time
Pr.6
Deceleration time
Pr.7
Default
Setting range
value
1 to 4000000pulse/s
0pulse/s
10 to 4000000pulse/s
200000
(Set in the unit of
pulse/s
10pulse/s.)
2 to 9999ms
300ms
Check timing
Setting condition
The data can be set anytime.
Note that the set data at the
rise (ON) of a JOG start
signal (Y24, Y25) are used
When a JOG
for the operation. If the data
start signal
are written when BUSY
(Y24, Y25) is
signal (X14) is on, the data
turned on
will be accepted at the rise
(ON) of the next JOG start
signal (Y24, Y25).
CHAPTER 10 JOG OPERATION
Buffer
memory
of the set
address
data
(decimal)
84
85
20
21
22
23
207
10