5 Calibration
5.2 Fine calibration
5.2 Fine calibration
General
This procedure must be applied at the first start or after mechanical intervention
(motor change, gearbox).
1
2
3
4
5
6
7
8
9
176
Action
Using the FlexPendant, jog the carriage close to
the calibration gauge position.
Move the track until the calibration holes line up.
Insert the calibration pin (3HAW107700354).
A dowel pin diameter 8 mm can also be used.
Tap ABB on the top left of the FlexPendant
Tap Calibration.
Select the desired mechanical unit.
Tap Fine calibration.
Select the desired axis.
Tap Calibrate.
© Copyright 20042018 ABB. All rights reserved.
Note/Illustration
xx1800002077
xx1800001960
Product manual - FlexTrack IRT501-66/66R/90/90R
3HAW050008590-001 Revision: C