Operation Manual / Power2 850-M / 4.1 Low-pressure stage
4 Disassembly and assembly / 4.11 Installing the cartridge group
Control dimension after installing cartridge group
CAUTION
Control dimension outside the tolerance value
If the control dimension is out of tolerance, the cartridge group has not
been correctly installed and can be the cause of serious damage to the ma-
chine or property.
Remove and reinstall the cartridge group.
u
Always replace jammed gasket rings with new ones.
u
If the control dimension is still out of tolerance, contact an ABB Tur-
u
bocharging Service Station.
Fig. 24: Measuring control dimension X
After installing the cartridge group, the control dimension (X) must be measured.
Table 10: Control dimension X
© Copyright 2019 ABB. All rights reserved.
Control dimension X
[mm]
63.0 ±0.1
HZTL4062_EN
Revision A
March 2019