Operation Manual / Power2 850-M / 4.1 Low-pressure stage
4 Disassembly and assembly / 4.13 Installing the wall insert
Fig. 27: Installing wall insert 2
Part number
Tightening torque
72002
M16x334
50 Nm
Table 13: Tightening torque (72002)
1. Remove plate (90032), screw (90656), nut (90432) and plates (90031).
2. Remove the bracket (90030).
3. Detach speed measurement cable from provisional holder and insert cable con-
nector (86515).
4. Fit four studs (72002) in the upper area. Observe the tightening torque.
© Copyright 2019 ABB. All rights reserved.
HZTL4062_EN
Revision A