ZH – R1…R4 快速安装指南 ACH580-01 0.75 to 250 kW hardware manual (3AXD50000162420 [英文])中 的 Technical data(技术数据)一章。 保护变频器和输入电缆 III gC IV uR or aR 请参阅表 (第 页)和 (第 页);(UL:第 页的表 V UL )了解熔断器的信息。 如果使用gG熔断器,请确保熔断器的熔断时间少于0.5秒。遵循当地法规。 在墙上安装变频器 R1…R4 Figures A 请参阅第 页的图 。...
ZH – R5 快速安装指南 ACH580-01 (0.75 to 250 kW) hardware manual (3AXD50000162420)中的 Technical data (技术数据) 一章。 保护变频器和输入电缆 III gC IV uR or aR V UL 请参阅表 (第 页)和 (第 页);(UL:第 页的 表 62)了解熔断器的信息。 如果使用gG熔断器,请确保熔断器的熔断时间少于0.5秒。遵循当地法规。 在墙上安装变频器 R5 Figures A 请参阅第 页的图...
EN – R1…R4 Quick installation guide This guide briefly describes how to install the drive. For complete information on installation, see ACH580-01 (0.75 to 250 kW) hardware manual (3AXD50000044839 [English]). For start-up instructions, see chapter EN – Quick start-up guide page 51.
-15 to +50 °C (+5 to +122 °F). No condensation or frost is allowed. For more information on the ambient temperature and derating, see chapter Technical data in ACH580-01 (0.75 to 250 kW) hardware manual (3AXD50000044839 [English]). Protect the drive and input power cable...
EN – R1…R4 Quick installation guide 33 Switch off the power and open the cover See figure on page 67. 2. Switch off the power from the drive. 3. Remove the front cover: Loosen the retaining screw, if any, with a screwdriver (3a) and lift the cover from the bottom outwards (3b) and then up (3c).
34 EN – R1…R4 Quick installation guide Ground-to-phase varistor The ground-to-phase varistor is not suitable for use on an IT (ungrounded) system. Disconnect the ground-to-phase varistor before connecting the drive to the supply network. Check the table on page 34. WARNING! Do not install the drive with the ground-to-phase varistor connected on an IT system (an ungrounded power system or a high- resistance-grounded [over 30 ohms] power system), otherwise the varistor circuit can...
EN – R1…R4 Quick installation guide 35 Disconnect EMC filter or ground-to-phase varistor, if needed To disconnect the internal EMC filter or ground-to-phase varistor, if needed, do as follows: 1. Switch off the power from the drive. 2. Open the front cover, if not already opened, see figure on page 67.
Page 36
36 EN – R1…R4 Quick installation guide Connect the power cables See figures (page 67), C2, D, E1, E2, F, G1, R1…R4 Figures H (page 69). 1. Remove the rubber grommets from the cable entry. Use symmetrical shielded cable for motor cabling. If the cable shield is the sole PE conductor for drive or motor, make sure that is has sufficient conductivity for the PE.
EN – R1…R4 Quick installation guide 37 Connect the control cables See figures on page 69. It shows an example with one analog signal cable and one digital signal cable. Make the connections according to the default configuration in use. The default connections of the HVAC default configuration are shown in section Default I/O connections on page 38.
OUT1 Safe torque off. Factory connection. Both circuits OUT2 must be closed for the drive to start. See chapter The Safe torque off function in ACH580-01 (0.75 SGND to 250 kW) hardware manual (3AXD50000044839 [English]). Total load capacity of the Auxiliary voltage output +24V (X2:10) is 6.0 W (250 mA / 24 V DC).
EN – R1…R4 Quick installation guide 39 Install optional modules, if any See chapter Electrical installation in ACH580-01 (0.75 to 250 kW) hardware manual (3AXD50000044839 [English]). Reinstall cover See figure on page 70. 1. Put the tabs on the inside of the cover top in their counterparts on the housing (1a) and then press the cover at the bottom (1b).
EN – R5 Quick installation guide This guide briefly describes how to install the drive. For complete information on installation, see ACH580-01 (0.75 to 250 kW) hardware manual (3AXD50000044861 [English]). For start-up instructions, see chapter EN – Quick start-up guide page 51.
-15 to +50 °C (+5 to +122 °F). No condensation or frost is allowed. For more information on the ambient temperature and derating, see chapter Technical data in ACH580-01 (0.75 to 250 kW) hardware manual (3AXD50000044861 [English]). Protect the drive and input power cable...
EN – R5 Quick installation guide 43 Switch off the power and open the cover See figure on page 71. 2. Switch off the power from the drive. 3. IP21, Remove the module cover: Loosen the retaining screws with a screwdriver (3a) and lift the cover from the bottom outwards (3b) and then up (3c).
Page 44
44 EN – R5 Quick installation guide Check from the table below if you have to disconnect the EMC filter (EMC) or ground- to-phase varistor (VAR). For instructions on how to do this, see page 45. Frame Ground- Symmetrically Corner grounded IT systems sizes filter...
EN – R5 Quick installation guide 45 Disconnect EMC filter or ground-to-phase varistor, if needed To disconnect the internal EMC filter or ground-to-phase varistor, if needed, do as follows: 1. Switch off the power from the drive. 2. Open the front cover, if not already opened, see figure on page 71.
46 EN – R5 Quick installation guide Connect the power cables See figures (page 72), and E. 1. Attach the residual voltage warning sticker in the local language next to the control board. 2. Remove the shroud on the power cable terminals by releasing the clips with a screwdriver and pulling the shroud out.
EN – R5 Quick installation guide 47 Connect the control cables See figure on page 73. It shows an example with one analog signal cable and one digital signal cable. Make the connections according to the default configuration in use. The default connections of the HVAC default configuration are shown in section Default I/O connections on page 48.
OUT1 Safe torque off. Factory connection. Both circuits OUT2 must be closed for the drive to start. See chapter The Safe torque off function in ACH580-01 (0.75 SGND to 250 kW) hardware manual (3AXD50000044861 [English]). Total load capacity of the Auxiliary voltage output +24V (X2:10) is 6.0 W (250 mA / 24 V DC).
EN – R5 Quick installation guide 49 Install optional modules, if any See chapter Electrical installation in ACH580-01 (0.75 to 250 kW) hardware manual (3AXD50000044861 [English]). Reinstall cover See figure on page 73. 1. IP21, Reinstall the box cover: Slide the cover upwards (1a) and tighten the retaining screws (1b).
EN – Quick start-up guide 51 EN – Quick start-up guide This guide describes how to start-up the drive using the First start assistant on the HVAC control panel. For complete information on start-up, see ACH580 firmware manual (3AXD50000027537 [English]). Before you start Ensure that the drive has been installed as described in chapter EN –...
Page 52
Refer to the motor nameplate for the following nominal value settings of the motor. Enter the values exactly as shown on the motor nameplate. Example of a nameplate of an induction (asynchronous) motor: ABB Motors motor M2AA 200 MLA 4 IEC 200 M/L 55 Ins.cl.
Page 53
EN – Quick start-up guide 53 To change a value in an edit view: • Use to move the cursor left and right. • Use to change the value. Press (Save) to accept the new setting, or press (Cancel) to go back to the previous view without making changes.
Page 54
54 EN – Quick start-up guide Change the units shown on the panel if needed. • Go to the edit view of a selected row by pressing • Scroll the view with Go to the next view by pressing (Next). To select a value in an edit view: •...
Page 55
EN – Quick start-up guide 55 The Home view monitoring the values of the selected signals is shown on the panel.
Page 56
56 EN – Quick start-up guide 2 – Hand/Off/Auto operation The drive can be in remote control or local control, and in local control there are additionally two different modes. Remote control: Drive is controlled from the I/O or the fieldbus. •...
Ratings and fuses I IEC, U = 400 V Type Input Max. Output ratings Heat Air flow Frame ACH580 rating current dissipation size Nominal use -01- 3-phase U = 400 V (380…415 V) 02A7-4 0.75 03A4-4 04A1-4 05A7-4 07A3-4 10.1 09A5-4 13.0 12A7-4...
III gC Type Min. Input gG (IEC 60269) North short- current American ACH580 Nominal Voltage ABB type circuit -01- type current rating 60269 current ACH580 size -01- 3-phase U = 400 or 480 V (380…415 V or 440…480 V) = 480 V...
Page 59
V UL UL/NEC Input IEC type current type ACH580 Bussmann UL class Maximum Voltage -01- ACH580 type current rating -01- 02A1-4 JJS-15 02A7-4 03A0-4 JJS-15 03A4-4 03A5-4 JJS-15 04A1-4 04A8-4 JJS-15 05A7-4 07A6-4 JJS-15 09A5-4 012A-4 12.0 JJS-15 12A7-4 014A-4 14.0 JJS-30 018A-4...
3AXD00000586715.xls III gC Type Min. Input gG (IEC 60269) North short- current American ACH580 Nominal Voltage ABB type circuit -01- type current rating 60269 current ACH580 size -01- 3-phase U = 400 or 480 V (380…415 V or 440…480 V)
Page 62
V UL UL/NEC Input IEC type current type ACH580 Bussmann UL class Maximum Voltage -01- ACH580 type current rating -01- 077A-4 JJS-100 096A-4 JJS-150 106A-4 3AXD00000586715.xls J...