Switch and Module Weights and Quantities
Switch and Module Weights and Quantities
Component
Cisco Nexus 93180YC-FX3 Chassis (N9K-C93180YC-FX3)
Fan Module
– Port-side exhaust (blue) (NXA-FAN-35CFM-PE)
– Port-side intake (burgundy) (NXA-FAN-35CFM-PI)
Power Supply module
– 650-W AC port-side exhaust (blue) (NXA-PAC-650W-PE)
– 650-W AC port-side intake (burgundy) (NXA-PAC-650W-PI)
– 1200-W HVAC/HVDC dual-direction (white) (N9K-PUV-1200W)
– 930-W DC port-side exhaust (blue) (NXA-PDC-930W-PE)
– 930-W DC port-side intake (burgundy) (NXA-PDC-930W-PI)
Transceiver and Cable Specifications
To see the transceiver specifications and installation information, see
interfaces-modules/transceiver-modules/products-device-support-tables-list.html.
Switch Power Input Requirements
The following table lists the typical amount of power that the switch consumes. It also lists the maximum
amount of power that you must provision for the switch and power supply for peak conditions.
Note
Switch
Cisco Nexus 93180YC-FX3
Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide
52
Some power supplies have capabilities that are greater than the maximum power requirements for a switch.
To determine the power consumption characteristics for the switch, use the typical and maximum requirements
that are listed in the following table.
Typical Power
Maximum Power
Consumption (AC or DC)
Consumption (AC or
DC)
375
600 W
System Specifications
Weight per Unit
Quantity
21 lb (9.52 kg)
1
—
4
0.26 lb (0.12 kg)
—
2 (1 for
operations
2.42 lb (1.1 kg)
and 1 for
2.42 lb (1.1 kg)
redundancy)
https://www.cisco.com/c/en/us/support/
Heat Dissipation
Requirement
2047.285 BTUs
per hour