Chapter 4
Connecting the Cisco uBR7225VXR Router to the Cable Headend
Figure 4-8
Change the spectrum analyzer settings to view the digital channel power. This setting enables you to see
Step 7
if there is too much power on the upconverter output. In
+64.31 dBmV, which is beyond the DOCSIS-specified range of +50 to +61 dBmV.
Tip
A spectrum analyzer might become overloaded and produce false readings (such as internally generated
spurs) when measuring a signal at this amplitude.
Figure 4-9
Adjust the power on the upconverter output to ensure that it is between +50 and +61 dBmV. In
Step 8
Figure
OL-17309-01
Measuring the RF Signal at the Upconverter Output—Overload Condition Corrected
with Attenuation
Measuring the RF Signal at the Upconverter Output—Upconverter Output Level Too
High
4-10, the upconverter output is reading +57.06 dBmV, which is within the correct range.
Cisco uBR7225VXR Universal Broadband Router Hardware Installation Guide
Measuring the Downstream RF Signal
Figure
4-9, the upconverter output is reading